You need a 5.5kw generator to run a 5.5kw motor.
yes
Sir, what is the cable size for 1.5kw 3phase induction motor 400v?
Yes, however, the RPM will increase by 20%, if the motor is connected to a shaft or driving something that can not handle the torque, then you might run to heating issues or performance issues.
3 core 35 sq mm alu. Or 3 core 25 sq mm cup.
yes can run but motor only delivers 90%rated power because v/f less by 10%
I HAVE A 15KW 50Hz 400V VEM MOTOR , I WANT TO RENEWAL THE GREASE
Power in a 3 phase circuit is given by W=√3*V*I*cosφ therefore transposing the formula gives: I=W/√3*V*cosφ where I=current in amps, W=power in watts, V=line voltage, cosφ=power factor (this should be on the motor plate, if not you could use 0.9) Regards ninenix
A direct on line starter, often abbreviated DOL starter, is a widely-used starting method of electric motors. The term is used in electrical engineering and associated with electric motors. There are many types of motor starters, the simplest of which is the DOL starter. A motor starter is an electrical/electronic circuit composed of electro-mechanical and electronic devices which are employed to start and stop an electric motor. Regardless of the motor type (AC or DC), the types of starters differ depending on the method of starting the motor. A DOL starter connects the motor terminals directly to the power supply. Hence, the motor is subjected to the full voltage of the power supply. Consequently, high starting current flows through the motor. This type of starting is suitable for small motors below 5 hp (3.75 kW). Reduced-voltage starters are employed with motors above 5 hp. Although DOL motor starters are available for motors less than 150 kW on 400 V and for motors less than 1 MW on 6.6 kV. Supply reliability and reserve power generation dictates the use of reduced voltage or not. A very well-known motor starter is the DOL Starter of a 3-Phase Squirrel-Cage Motor. This starter is sometimes used to start water pumps, compressors, fans and conveyor belts. With a 400V, 50 Hz, 3-phase supply, the power circuit connects the motor to 400V. Consequently, the starting current may reach 3-8 times the normal current. The control circuit is typically run at 24V with the aid of a 400V/24V transformer
If I consider power factor is 0.85 & motor efficiency is 95% then you have required 4 sq mm wire which is able allow passing 25.47 A current trough it.