Q: What size pipe for a 150 amp 3 phase sub panel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you install a 150 amp meter base and still have a 100 amp main panel?

The wire size in a meter stack is governed by the size of the first over current device.


What phase is water in at 1 ATM pressure and 150 and degC?

It is in the gas phase.


What is the gauge equivalent of schedule 40 pipe?

150


Need a vacuum pipe diagram for a 1992 Honda Ballade 150 16v carburetor?

vacuum pipe diagram for honda ballade 150 carburator


How many feet of 8 pipe will it take to hold 150 gallons of water?

An 8-inch pipe must be 57.4 feet long to contain 150 gallons of water.


Would a 3 phase 95 millimeter for each phase 150 meters long cable be enough for a 285 kva genset?

Yes, a 3 phase 95 millimeter for each phase 150 meters long cable is enough for a 285 KVA genset.


What is thickness of 150 nb C Class pipe?

150nb


What would cause the instrument panel on a 1997 Ford F-150 not to work?

What would cause the instrument panel on a 1997 ford pickup 150 not to work?


What is the average size for service panel for a 1200sqft house built in 1995?

It was probably a 150 amp service back in 1995. Todays services are usually 200 amps.


Do you need to change the wire size going from 100 amp service to 150 amp service?

Yes, the wire size has to be increased. The existing 100 amp service will now probably have a #3 conductor with an insulation factor of 75 or 90 degrees C which is rated for 100 and 105 amps respectively. Increasing to a 150 amp service will use a #1/0 wire size. If you are thinking of an upgrade, skip the 150 amp service and go to a 200 amp panel. New homes are installing 200 amp 42 circuit panels. The extra cost is only reflected in the materials as the labour costs will be the same regardless whether a 150 amp or a 200 amp panel is installed. The wire size for a 200 amp panel is #3/0. With an insulation factor of 75 or 90 degrees C the rating is 200 or 210 amps respectively.


What size cable for single phase 240volt carrying 65amps over 150 meters?

A 2/0 AWG copper conductor will limit the voltage drop to 3% or less when supplying 65 amps for 150 metres on a 240 volt system.


What is the clearance in air required for 150 kv bil.?

Phase to phase clearance should be around 11.5 inches.