answersLogoWhite

0


Best Answer

High resistance on the feeder to the load will cause voltage drop at the load end of the circuit. If this is happening, do the calculations for voltage drop, using the amperage of the load, voltage of the load, the size of the wire feeding the load and the distance from the distribution panel to the load.

User Avatar

Wiki User

8y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What would cause high voltage drop readings?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What cause the voltage drop in shunt generator when its loaded?

because the voltage likes to drop


Should there be voltage readings across a closed contact?

For all practical purposes NO. The only voltage measured will be the voltage drop of the contact itself. This should be very low if the contact is good.


I have a 5000 watt Honda generator. How much of a voltage drop will a 25 foot portable generator cord cause?

A 25 foot cord will not cause enough voltage drop to worry about.


What is voltage drop per foot?

Voltage drop is caused by resistance. From the equation V=IR the voltage across that resistance can be calculated. For a uniform conductor the resistance is linear with the length R=kx where k is in ohms per foot. For a given current, the voltage drop V=Ikx so the voltage drop per foot is Ik. Voltage drop per foot can be measured, allowing a calculation of voltage drop for very long lengths of conductor such as power transmission lines. This is a reasonable approximation as long as the total voltage drop in transmission is small relative to the supply voltage. If the voltage drop is large, the current will be limited by the total resistance. This implies that long distance transmission lines should be high voltage, because 1 megawatt at 10,000 volts requires 100 amps, while at 100,000 volts it only requires 10 amps. The voltage drop per foot for the same conductor would be 10 times as large at 10 times the current, and the power loss (I*IR) would be 100 times as large. For alternating current, inductance can be a factor; this implies that relatively low frequency would be preferred.


What is the difference between voltage forward voltage and voltage drop?

Voltage is the potential difference between the source & any point in the circuit. The forward voltage is the voltage drop across the diode if the voltage at the anode is more positive than the voltage at the cathode (if you connect + to the anode). Voltage drop means, amount of voltage by which voltage across load resistor is less then the source voltage.

Related questions

Can a corroded battery cause a voltage drop?

Yes, a corroded battery can cause an intermittent voltage drop.


What cause the voltage drop in shunt generator when its loaded?

because the voltage likes to drop


Should there be voltage readings across a closed contact?

For all practical purposes NO. The only voltage measured will be the voltage drop of the contact itself. This should be very low if the contact is good.


I have a 5000 watt Honda generator. How much of a voltage drop will a 25 foot portable generator cord cause?

A 25 foot cord will not cause enough voltage drop to worry about.


What would be the voltage drop across two 25 resistors in parallel if the source voltage were equal to 9v?

The voltage would 9V minus any drop in the battery.


What would cause my outside temp display on my 2001 Buick Century Limited Climate control drop to -38 degrees when it's 60 degrees outside?

If the sensor is blocked or has mud on it, the readings will be inaccurate, and give completely false readings.


Why would the volt meter bounce when the turn signal is on in a 1994 Buick Regal?

It all depends on where you are reading the voltage. If you are reading it at the bulb, then every time the light turns on, the current that it is drawing will cause the voltage to drop slightly due to resistence in the line from the battery and the corresponding voltage drop to the bulb. If there is a very large drop, there could be a short in the line with that bulb. The bulb would not get full brightness then.


What would the results of voltage drop test be if the circuit is open?

voltage drop is zero bcz in open ckt current will be zero


The voltage drop across a resistor is 1.0 V for a current of 3.0 A in the resistor what is the current that will produce a voltage drop of 9.0 V across the resistor?

The resistor is 1/3 of an ohm. A 9 volt drop across the resistor would cause a draw of 27 amps through the resistor. The wattage you would need for that resistor is at least a 243 watts.


What is volts drop?

the voltage drop means whenever the conductor passing through the supply voltage, according to the resistivity property to reduces the some amount of voltage that drop is known as voltage drop for example the resistance is used to drop the voltage to the circuit.............................................


Is there a rule to distance of cable from a power source to low voltage lighting without voltage drop and do you have to put transformers or outlets in the yard?

Voltage drop depends on the size & length of the wire and the wattage of the bulbs. If they make an LED replacement bulb , you would hardly notice the voltage drop.


What is the voltage drop using?

Voltage drop is caused by circuit resistance