Transmission circuits are prone to earth faults.Only star connection permits flow of earth fault current and the operation of earth fault relays.
A step up transformer is used at this junction in the electrical transmission system.
3 contactors are used: one for the main incoming service lines, one to make the star connection and one for the delta connection. Auxiliary to the contactors, a delay timer, adjustable from 500-1000 seconds, is used to shift from star to delta configuration.
connection of the ground of all the transmission lines and used as a communication cable between protection devices
No difference. Y is used as a symbol to indicate the star connection.
The term, 'star point', refers to the common point of connection for the three windings of a star-connected (wye-connected) transformer connection. The star point is usually earthed (grounded) and provides the neutral point of the connection.
The power of all three phases can be transmitted on three conductors.A star connection, as opposed to a delta, provides a grounding reference. Also, for ground faults on the secondary (assuming no delta third winding, or source third winding) will be a direct ratio similar to phase faults, instead of 57%. Another reason is to avoid the inherent phase shift involved in a delta/star configured transformer.Another AnswerA 'star-connected' secondary is the standard European connection for a three-phase distribution transformer, as it provides a line voltage of 400 V together with a phase voltage (i.e. line to neutral) of 230 V.
The definition of star connection is a connection of the ends of phase windings at the star point.
There are essentially 2 types of connections for a 3 phase AC transmission lines Star and Delta , Star is a 4 wire connection with each phase supplying potential with respect to a common ground wire , while delta is 3 wire connection with any single phase at one given time acting as a ground , for transmission reducing one wire makes a lot of cost difference hence it is favored
A step up transformer is used at this junction in the electrical transmission system.
hahahaa
because usually the step down transformers are used for supply so it requires neutral(return)path, we cant take neutral path through delta connection hence the star connection is used and mostly in step-down the star connection is used.
3 contactors are used: one for the main incoming service lines, one to make the star connection and one for the delta connection. Auxiliary to the contactors, a delay timer, adjustable from 500-1000 seconds, is used to shift from star to delta configuration.
star delta connection is used reduce high starting current of the motor. you can see the below diagram if you need anything more details... let me know
two contecter <<>> There are three contactors used in a Star Delta configuration.
connection of the ground of all the transmission lines and used as a communication cable between protection devices
No difference. Y is used as a symbol to indicate the star connection.
i think its use for 3 phase connection.