No. Braided wire is not considered "current-carrying". It is not sold or maufactured via AWG specs. It is manufactured via weight per foot. Braided wire is used for grounding purposes only.
In the United States, if the wire is #8 copper or larger (smaller number) it will work fine on a 40 amp breaker. If the wire is #10 copper, there is something wrong with the breaker if it does not fit. Pull the breaker out of the panel and look into where the wire terminates to see why the #10 wire won't fit.
An individual would use a braided hose instead of a traditional wire covering if the wires being covered needed more protection. The braided hose is stronger than a wire covering.
Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.
Yes, if you are running it no farther than 100 feet. If you are going over 100 feet use AWG # 10 wire on the 20 amp breaker.
Yes.Additional InformationBreakers and fuses protect the wires to prevent fire. The 100 Amp breaker in the meter base (main) protects the wire from the meter base to the breaker panel. The 50 Amp breaker in the breaker panel protects the wire from the breaker panel to the outlet. Sometimes the 100 amp main breaker is located in the panel.If you are asking "Can you use two 50 amp breakers for the main breakers with a 100 amp service, then yes you can. The National Electrical Code allows you to use up to 6 breakers as the main overcurrent protection.
An individual would use a braided hose instead of a traditional wire covering if the wires being covered needed more protection. The braided hose is stronger than a wire covering.
In the United States, if the wire is #8 copper or larger (smaller number) it will work fine on a 40 amp breaker. If the wire is #10 copper, there is something wrong with the breaker if it does not fit. Pull the breaker out of the panel and look into where the wire terminates to see why the #10 wire won't fit.
Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.
Yes, if you are running it no farther than 100 feet. If you are going over 100 feet use AWG # 10 wire on the 20 amp breaker.
Yes.Additional InformationBreakers and fuses protect the wires to prevent fire. The 100 Amp breaker in the meter base (main) protects the wire from the meter base to the breaker panel. The 50 Amp breaker in the breaker panel protects the wire from the breaker panel to the outlet. Sometimes the 100 amp main breaker is located in the panel.If you are asking "Can you use two 50 amp breakers for the main breakers with a 100 amp service, then yes you can. The National Electrical Code allows you to use up to 6 breakers as the main overcurrent protection.
Use a 30 amp breaker.
No. A 20 amp breaker needs 12 gauge wire.
The breaker you use is determined by the size of the wire in the wall not by what is being connected to that circuit. If you have 14/2 wire then use a 15 amp breaker. If you have 12/2 wire then use a 20 amp breaker. The breaker protects the wiring not the item connected.
The breaker you use is determined by the size of the wire in the wall not by what is being connected to that circuit. If you have 14/2 wire then use a 15 amp breaker. If you have 12/2 wire then use a 20 amp breaker. The breaker protects the wiring not the item connected.
The question isn't what you're powering with a particular gauge of wire, but what's the current draw. If the metal halide light can run on a 15 Amp breaker (from the breaker panel), fine use your metal halide in your residential application and run it on the 14 gauge wire.
You use the correct size breaker depending on the size wire in the circuit. If the circuit is wired with AWG #12 wire use a 20 amp breaker. If it is wired with AWG #14 wire then use a 15 amp breaker.
For typical residential house wiring 12 AWG wire is required for a 20 Amp breaker. If you change out the breaker for a 25 A breaker you would have to rewire the circuit with 10 AWG. In that case you could up the breaker to 30 Amps. All outlets and switches should be rated at the same voltage and current as the breaker.