answersLogoWhite

0

How autoclave works in gas law?

Updated: 8/10/2023
User Avatar

Wiki User

12y ago

Best Answer

An autoclave is a device-absolutely essential for all tattoo and piercing studios without exceptions-that sterilizes tools and jewelry through a process of heated and pressurized steam. Usually this means 274 degrees at 18 PSI, although different autoclaves will use different methods. While some people may substitute a pressure cooker for an autoclave, a pressure cooker is not properly gauged, and its moisture may damage the integrity of the autoclaving bags. This is not to say that proper sterilization does not occur, only that the cycle should be run longer than required and a spore test be taken and passed monthly to insure this. Bags allowed to dry, paper side up, will be no less structurally fine when dry than those sterilized in an autoclave. For all the trouble, it's better to just buy an autoclave-they only cost a few hundred dollars. There are several different "types" of autoclave; gravity displacement, positive pressure displacement, and negative pressure (vacuum) displacement: * The autoclave at your local tattoo or piercing studio (in the US) is most likely a gravity displacement autoclave, or type "N". This design of autoclave generally has a heating element fully or partially submerged in a pool of water in the bottom of the autoclave chamber, along with a fill hole that transfers water from a reservoir to the autoclave chamber. As the water in the pool is heated it begins to evaporate, forming steam. Steam is lighter then air, as the chamber fills with steam the majority of air in the chamber is pushed to the bottom of the chamber, and escapes via the fill hole which is connected to a temperature sensitive diaphragm that closes once it is sufficiently heated. Once the diaphragm closes pressure builds up inside the autoclave chamber. The benefit of this type of autoclave is it's simplicity, the drawback with gravity displacement autoclaves is they are only designed to function properly with solid unwrapped instruments, however there has been no indication that a gravity displacement autoclave, properly loaded with properly processed instruments is unsafe for use in the modification industry. * A positive pressure displacement autoclave improves on the design of a gravity displacement autoclave (see above) by creating the steam in a separate internal unit, sometimes called a "steam generator". Once the amount of steam needed to displace air in the chamber is produced a valve opens and a pressurized burst of steam enters the autoclave chamber, resulting in a higher percentage of air from the chamber being removed then with a gravity displacement autoclave, this decreases autoclave cycle times. Currently the most widely distributed and used if not the only positive pressure displacement autoclave is the Statim line of autoclaves. The drawbacks to positive pressure displacement autoclaves are the high initial cost, and the fact they generally have a smaller chamber. * Negative pressure, or vacuum displacement autoclaves, also known as type "S", have a separate internal "steam generator", as well as a vacuum pump. After the autoclave chamber is closed the vacuum pump removes all air form the chamber, and as above, steam is injected into the chamber. Negative pressure displacement autoclaves are able to attain some of the highest sterility assurance level or SAL. Negative displacement autoclaves generally have a forced filtered air drying system that allows the autoclave packages to be throughly dries before contacting any ambient air. The drawback back to negative pressure displacement autoclaves is the cost, and sometimes the size of these systems. * The last "type" of steam autoclave is type "B" for Big, and the name speaks for itself. These systems are more or less enlarged negative pressure displacement autoclaves (there are enormous gravity displacement autoclaves as well, but they are still type "N", and not usually used in the medical or modification industries). The steam generator for Type "B" autoclaves is usually a separate stand alone unit, and the autoclave chamber is sometimes large enough to physically enter. Due the large scale and astronomical price tag of these autoclaves they are rarely, if ever used in the modification industry.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

15y ago

An autoclave is a device-absolutely essential for all tattoo and piercing studios without exceptions-that sterilizes tools and jewelry through a process of heated and pressurized steam. Usually this means 274 degrees at 18 PSI, although different autoclaves will use different methods. While some people may substitute a pressure cooker for an autoclave, a pressure cooker is not properly gauged, and its moisture may damage the integrity of the autoclaving bags. This is not to say that proper sterilization does not occur, only that the cycle should be run longer than required and a spore test be taken and passed monthly to insure this. Bags allowed to dry, paper side up, will be no less structurally fine when dry than those sterilized in an autoclave. For all the trouble, it's better to just buy an autoclave-they only cost a few hundred dollars. There are several different "types" of autoclave; gravity displacement, positive pressure displacement, and negative pressure (vacuum) displacement: * The autoclave at your local tattoo or piercing studio (in the US) is most likely a gravity displacement autoclave, or type "N". This design of autoclave generally has a heating element fully or partially submerged in a pool of water in the bottom of the autoclave chamber, along with a fill hole that transfers water from a reservoir to the autoclave chamber. As the water in the pool is heated it begins to evaporate, forming steam. Steam is lighter then air, as the chamber fills with steam the majority of air in the chamber is pushed to the bottom of the chamber, and escapes via the fill hole which is connected to a temperature sensitive diaphragm that closes once it is sufficiently heated. Once the diaphragm closes pressure builds up inside the autoclave chamber. The benefit of this type of autoclave is it's simplicity, the drawback with gravity displacement autoclaves is they are only designed to function properly with solid unwrapped instruments, however there has been no indication that a gravity displacement autoclave, properly loaded with properly processed instruments is unsafe for use in the modification industry. * A positive pressure displacement autoclave improves on the design of a gravity displacement autoclave (see above) by creating the steam in a separate internal unit, sometimes called a "steam generator". Once the amount of steam needed to displace air in the chamber is produced a valve opens and a pressurized burst of steam enters the autoclave chamber, resulting in a higher percentage of air from the chamber being removed then with a gravity displacement autoclave, this decreases autoclave cycle times. Currently the most widely distributed and used if not the only positive pressure displacement autoclave is the Statim line of autoclaves. The drawbacks to positive pressure displacement autoclaves are the high initial cost, and the fact they generally have a smaller chamber. * Negative pressure, or vacuum displacement autoclaves, also known as type "S", have a separate internal "steam generator", as well as a vacuum pump. After the autoclave chamber is closed the vacuum pump removes all air form the chamber, and as above, steam is injected into the chamber. Negative pressure displacement autoclaves are able to attain some of the highest sterility assurance level or SAL. Negative displacement autoclaves generally have a forced filtered air drying system that allows the autoclave packages to be throughly dries before contacting any ambient air. The drawback back to negative pressure displacement autoclaves is the cost, and sometimes the size of these systems. * The last "type" of steam autoclave is type "B" for Big, and the name speaks for itself. These systems are more or less enlarged negative pressure displacement autoclaves (there are enormous gravity displacement autoclaves as well, but they are still type "N", and not usually used in the medical or modification industries). The steam generator for Type "B" autoclaves is usually a separate stand alone unit, and the autoclave chamber is sometimes large enough to physically enter. Due the large scale and astronomical price tag of these autoclaves they are rarely, if ever used in the modification industry. TAKEN FROM BMEZINE.COM

This answer is:
User Avatar

User Avatar

Wiki User

12y ago

It is based on Gay-Lussac's Law. Autoclaves work by increasing the temperature in a sealed enclosure through the use of pressure. Water is introduced to help penetration of the heat as water transfers heat more efficiently than dry air. Generally the temperature needs to be increased to around 121 degrees Celsius over a period of time. This is generally around 15 - 20 minutes. The pressure increase helps the temperature of the steam to increase above its flash point (point of vapourisation). The moist hot air does the sterilization.

This answer is:
User Avatar

User Avatar

Wiki User

12y ago

In an autoclave, the high pressure ensures that the temperature is elevated well above the usual boiling point. This ensures sterilization of ordinary bacterial material.

But may be insufficient to destroy prion materials, for which the materials may have to be destroyed by incineration. Surgical Instruments pose a particular problem. NaOH or Cl are used to provide sufficient challenge to these materials.

This answer is:
User Avatar

User Avatar

Wiki User

9y ago

The working principle of an autoclave is that steam penetrates the object being cleaned. The steam is sometimes as high as 600 degrees.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How autoclave works in gas law?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What gas law is applied in the autoclave and explain the principle involve in their uses?

The ideal gas law is applied in the autoclave, which relates the pressure, volume, and temperature of a gas. In autoclaves, steam is used to create high pressure and high temperature conditions to sterilize equipment and materials by killing bacteria, viruses, and spores. The principle involved is that increasing the pressure and temperature inside the autoclave allows for more effective sterilization by denaturing proteins and disrupting cell structures.


What gas law could apply to how refrigerator works?

convection currents


How is the ideal gas law usually written?

PV=nRT also as an aside: Laws are described Law is described


What are the parts functions of autoclave?

The function of an autoclave in a microbiology laboratory is to sterilize the growth medium used in the laboratory without breaking down certain necessary nutrients required for the growth of microorganisms.


How much the autoclave volume?

how much autoclave volume ? laboratores


When was Autoclave - album - created?

Autoclave - album - was created in 1991.


How gas works?

so gas works by bubbles woohoo


What is autoclave paper?

paper that is used to wrap items that are placed in an autoclave for sterilization


What water do you use in an autoclave?

Demineralised water should best be used in an autoclave.


Which is the best Autoclave company in India for dental clinics?

Thymol India -- Leading Autoclave Machine Manufacturing Company in India. Quality autoclave, fully automatic, portal dental autoclaves available at very reasonable prices.


Why you have to autoclave the test test tubes?

If the test tubes need to be sterile, you would have to autoclave them.


What is difference between autoclave and oven?

In simple words, autoclave is a pressurized oven.