Control means, a timer cant control is speed directly, it can control its operation. A times will have NO nd NC contacts. Connect the motor in series with the timer contacts wrt desired operation

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How motor can control using timer contactor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

How do you wire up a 208v single phase motor with micro switch?

if you are using the pressure switch to control a 3phase pump chances are it already has a magnetic starter and a single pole control circuit i have seen small 3phase air compressors with the contacts driven right off the diaphragm bigger ones usually have 110 volt controls i would be concerned about the current rating of the switch if you are trying to switch the motor directly there are many single phase compressors that run directly from the pressure switch


State the terms associated with contactor starter used for starting and stopping induction motor some term and definition about contactors?

voltage, current, resistance, horsepower, contacts, overloads, coil, terminations, NEMA, IEC, NFPA 70 NEC, motor controls, NFPA70E . . . A contactor is a double make/break per phase switch that opens and closes the circuit to the motor by energizing a coil (electro-magnet) using a motor control circuit (usually, but not always a lower voltage than the motor circuit). The motor control circuit goes through a normally closed set of contacts that will open if the overloads that are in series with the motor circuit sense too much current going to the motor.


Can you connect three phase AC voltage directly to motor?

I assume your question relates to the need for a disconnect switch. To meet code you need a disconnect switch in the proximity of the motor so that should the need arise the motor can be disconnected for safe maintenance or in an emergency. The motor will work directly connected, but you will create a safety issue.


What are the types of motor controls?

motor can be control by using variable frequency drive


What is timer control in visual basic?

A timer is very useful in visual basic. It can be used to repeat events again and again at set intervals. Using other triggers, such as user inputs or button clicks, or even other timers, the timer can be turned off/on, and other properties such as the timer interval can be changed. It is a key feature of the language.

Related questions

What is the imporatance in using wyne delta motor control?

the important is contactor, timer, olr.....


How relay is used to control induction motor?

If you want to control induction motor using a control relay give neutral directly to the one point of coil of relay & one point of coil of contactor then give control supply through push button to second point of coil of relay. use one NO point of relay and give supply to coil of contactor. and also use one NO of contactor for holding the contactor & take OFF (NC) in the starting to stop motor after complition of work. It is jut like an Direct On-line starter.


Can you use normal relay to start a single phase motor pump?

It depends on what your definition of a normal relay is. If it is a small plug in relay to control the motor's contactor then there is no point. All pump motors need control to start and stop the pump. Whether it is done from a pressure switch or a float system it doesn't matter they both should control the motor's contactor and not the pump directly. Most small relays do not have the amp capacity in their contacts to handle inductive loads. Using a motor contactor also has the benefit to protect the motor with overload protection. Using the overload contacts in series with the control device allows the pump to go off line should an overload occur.


How do you wire up a 208v single phase motor with micro switch?

if you are using the pressure switch to control a 3phase pump chances are it already has a magnetic starter and a single pole control circuit i have seen small 3phase air compressors with the contacts driven right off the diaphragm bigger ones usually have 110 volt controls i would be concerned about the current rating of the switch if you are trying to switch the motor directly there are many single phase compressors that run directly from the pressure switch


What is a timer in a star delta starter?

A timer in star delta starter for a three phase motor is an electronic device designed to do the change over or transition from star connection - using which the motor suns on a reduced voltage and current and produces less torque - to the delta connection necessary for running the motor at its full power, using high voltage and current to produce a high torque. The timing interval that is set is dependent how long the motor needs to start up from standstill to normal speed. Some motors require 15 seconds for the initial startup in star connection and after that given value of time the timer signals to the star contactor to go to the open position and the main delta contactor to go to the closed position, thus forming the delta circuit.


Can you start 20kw motor on direct on line circuit?

No, the motor has to be connected to the line voltage through a set of fuses and then an electrical contactor. Also the motor must be thermally protected against overloads by using an overload block or heaters. This is to allow the motor contactor to drop out is a overload fault should occur.


How do you change star to delta?

In motor starters, this is usually done using contactors. Explanation of this can easily be done using a circuit diagram. There are three contactors, the main, star and delta contactors-all these contactors can be the same type. There are many ways of wiring a star delta but here I will only give a generalized answer. First, the main contactor and star contactors are energised thus the motor runs in star. After about 5 seconds, the timer which gets energized at the same time as the main and star contactors, switches its CONTACTS i.e the normally open closes and the normally close opens. This dienergize the star contactor and energized the delta contactor. Thus, the motor now runs in delta.


You found a 220volt coil on a 3 phase motor contactor and the one side of the coil is feed from B phase and the other side is also feed from B phase it would not pull in the contactor?

your not completing the circuit your only using one phase for a three phase motor


How do you wire 3 timers to one outlet using contactor?

A timer is a type of contactor. My answer assumes you do not need an additional contactor besides the timers and the timers are operated by the same circuit as the outlet. Each timer and the outlet need connections to the neutral and grounding conductors of the circuit. For the hot wires, you have to run your hot feed to each of the timers on the "line" side of the contacts. If the timer and the "line" side of the contacts are different connections you will have 2 connections in each timer. Then from the "load" side of the contacts you run wires that connect to the hot side of your outlet. At some point you will splice these together so you have only one hot wire connection to the outlet. Remember that timers, contactors, relays, etc., are simply switches operated by various means. You have the hot feed on one side and the "switch leg" to your load. You also have a control of some kind, and in your case your controls are the timers.


State the terms associated with contactor starter used for starting and stopping induction motor some term and definition about contactors?

voltage, current, resistance, horsepower, contacts, overloads, coil, terminations, NEMA, IEC, NFPA 70 NEC, motor controls, NFPA70E . . . A contactor is a double make/break per phase switch that opens and closes the circuit to the motor by energizing a coil (electro-magnet) using a motor control circuit (usually, but not always a lower voltage than the motor circuit). The motor control circuit goes through a normally closed set of contacts that will open if the overloads that are in series with the motor circuit sense too much current going to the motor.


What is a electrical contactor for?

An electrical contractor does the wiring for homes and businesses. They install the wiring and electrical components needed to run electricity. The question asks about a contactor, not a contractor. A contactor is a type of heavy duty electrical relay for using smaller voltages to control much larger voltages.


Can you connect three phase AC voltage directly to motor?

I assume your question relates to the need for a disconnect switch. To meet code you need a disconnect switch in the proximity of the motor so that should the need arise the motor can be disconnected for safe maintenance or in an emergency. The motor will work directly connected, but you will create a safety issue.