how will you start 3phase inuction motor using star delta stater
The motor terminal box should have six wires coming out of it.
revolving field theory of single phase induction motor
There is many type of starter on three phase circuit but the most common are 1: D.O.L (Direct on line). 2: Manual Star Delta Starter. 3: Automatic Star Delta Starter.
Open ended induction motor - i assume you are talking about split phase induction motor. With these motors old style speed controlling method using external resistors can be used. However this is now obsolete.
No.
by changin the freq usin an IGBT.
yes
why three phase induction motor is delta connected
You never need a starter for a three-phase motor.
I assume a 3 phase, AC induction motor. A star delta starter or a soft starter can be used. A soft starter is better compared to a star delta starter, but it is more expensive.
by motor starter
capacitive start motors start by themselves however a normal single phase induction motor requires a starter motor to 'kick-start' the motor into action.
A starter is unnecessary because the stator produces a rotating magnetic field.
Yes, by using a DOL Starter, which gives a controlled "soft-start" for the motor even though it is always connected in delta configuration.In this type of starting a 3-phase motor, full voltage is applied to the motor through relays and contactors. Its is the most common type of 3-phase motor starter used.DOL means Direct On-Line starter.
Yes, that is one of the major advantages of a three-phase induction motor.
That indicates a fault in the induction motor.
Star Delta starter control wiring ensures that initially the Motor winding is connected in Star and after set timer (few seconds) the winding gets connected in Delta automatically. There three power contactors and timers to make it happen.
The star delta motor starter circuit has to have a control voltage to energize the motor magnetic contractors. A phase failure relay monitors all three phases of the incoming supply lines. The phase failure relay also has auxiliary contacts on it. There are usually two sets of "C" form contacts. The control voltage for the starter circuit must be connected across the normally open (N.O.) contacts of one of these two sets. When the phase monitor is energized these N.O. contacts close supplying the control voltage to the circuitry of the star delta starters. If there is a phase interruption, phase reversal or phase loss, the phase failure relay will de-energize and the N.O. contacts will go back to their de-energized state. If the star delta motor starter is in use at the time, its control circuitry voltage will be lost and the delta motor magnetic contactor will open. The opening of this contactor will disconnect the motor from the failed three phase supply.