Basically it takes a higher current to start a fluorescent lamp that it does to sustain the arc. (It's higher current, not voltage. The voltage is constant.) The ballast regulates the current flow through the lamp.
Removing the voltage from devices requiring power will turn any device off.
yes, all conductors shall be insulated to the highest voltage utilised
Electronic Ballast plays a important part in lights.We need a Ballast Tester to test the electronic ballast performance of a fluorescent light fixture. This is a basic process that can be accomplished quickly once you understand the operation of the high voltage transformer. The high voltage transformer is also encased in an oil bath that reduces the heat created by the action of the transformer. A low voltage, generally 120 VAC, is transformed into a high voltage, generally in thousands of volts. There must be a continuity between the wires of the high voltage side in order for the circuit to operate correctly. Heat can damaged the internal connections of the ballast. By using a volt ohmmeter the internal circuit can be quickly checked. Not only in the voltage, but also in the current and others factors. If you want to learn more details about electronic ballast and relevant instruments, see the related link.
- S2 starters for ignition of low-voltage fluorescent TL lamps and series/single application in high voltage for lower wattages (4 - 22W) - S10 starters for ignition of high voltage fluorescent TL lamps for wide range of wattages (4 - 65W)
Electronic Ballast play a important part in the lights. So we need the device which is Ballast Tester to testing the electronic ballast performance of a fluorescent light fixture is a basic process that can be accomplished quickly once you understand the operation of the high voltage transformer. The high voltage transformer is also encased in an oil bath that reduces the heat created by the action of the transformer. A low voltage, generally 120 VAC, is transformed into a high voltage, generally in thousands of volts. There must be a continuity between the wires of the high voltage side in order for the circuit to operate correctly. Heat can damaged the internal connections of the ballast. By using a volt ohmmeter the internal circuit can be quickly checked. Not only in the voltage, but also in the current and others factors.
Electronic Ballast plays a important part in lights.We need a Ballast Tester to test the electronic ballast performance of a fluorescent light fixture. This is a basic process that can be accomplished quickly once you understand the operation of the high voltage transformer. The high voltage transformer is also encased in an oil bath that reduces the heat created by the action of the transformer. A low voltage, generally 120 VAC, is transformed into a high voltage, generally in thousands of volts. There must be a continuity between the wires of the high voltage side in order for the circuit to operate correctly. Heat can damaged the internal connections of the ballast. By using a volt ohmmeter the internal circuit can be quickly checked. Not only in the voltage, but also in the current and others factors. If you want to learn more details about electronic ballast and relevant instruments, see the related link.
In very simple terms the ballast provides an initial high voltage that is required to ionize the gas, thereby setting up an arc between the electrodes which in turn causes the bulb to light up. It also limits the current through the tube once it has started up. This prevents a voltage spike which would damage the bulb.
The electronic BALLAST is a circuit that limits the current through the fluorescent bulb to the design value. It also provides a pulse of high voltage to start the bulb conducting when it is switched on.
No, mica is a metamorphic rock. It is an excellent high voltage insulator.
Fuse is used to restrict the flow of current to the tube when it is supplied with very high voltage. Due to high voltage the tube may burst and even the electrical apparatus goes malfunctioning. Hence a resistor is used in the name of FUSE in the fluorescent lamp to prevent this sudden loss of the apparatus.
It was Alexandre-Edmond Becquerel who first conceived the idea of placing a fluorescent coating on the inner surface of a high voltage gas discharge tube but he didn't quite made it work properly. Tesla's investigations in the area of high-voltage RF power processing techniques did result in the very first high efficiency, high frequency lighting ballasts in 1892.
The function of any ballast in a lighting fixture is to raise the voltage high enough to strike an arc through the bulb or tube.