Best Answer

If it was preinstalled, it may have been adequate at the time of installation. It depends on the power requirements of the home. If this is a new install, the NEC has a minimum of 100A for service equipment. To be honest, I would install 200A minimum to allow for future expansion.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

8y ago

A 60 amp panel for this size of a home would be undersized. Most homes today are wired for the main service distribution to have a 200 amp 42 circuit panel. With this size square foot area there would probably be a sub panel fed from the main distribution panel. The sub panel would be in the range of a 100 amp 20 circuit panel.

This answer is:
User Avatar

User Avatar

Wiki User

15y ago

Toooo Small.

This answer is:
User Avatar

User Avatar

Wiki User

15y ago

too small

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: A 60 amp electrical service panel at a 2800 square foot home would be?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Would a 125 amp service panel be enough for a 1900 square foot house?

Absolutely not. A 60 amp whole house service is totally insufficient to power todays home, especially a 2800 square foot house. The NEC (National Electric Code) requires a minimum of 100 amp electrical service to any single family residence.


Why would the volts increase from the main panel to the sub panel?

Check the battery voltage on your tester. The voltage on the panel is the same throughout the whole electrical system.


What is electrical rating s o?

If you are referring to electrical cord that would be, Service grade Oil resistant


Are Westinghouse breakers compatible in Siemens panel?

Yes they are. I would only use them as a temporary measure until obtaining the correct Siemens breaker. There is a part of the electrical code about modifying electrical equipment which this could be construed as. If the panel certification is lost and the panel faults and a fire occurs, your insurance company might not cover the losses occurring from the fire.


200 amp main and would like to add another 100 amp service in another room how can you do this?

If you are doing this you are effectively limiting your main panel to 100 A with normal duty cycles. This can get complicated and an electrician is advised. But basically you have a 100A breaker that would typically be for 220-240 volt service and you would connect to the main of the second panel. The size of the wire between the two panels would have to be sized correctly and you would only bond ground and neutral at the main panel and not the branch panel. You might want to move some of the loads from the main panel to the branch depending on load calculations. If you know what you are doing and have access to a clamp on amp meter you could measure how much of the 200 Amps you are using at the current panel. This can be dangerous, so get an electrician or be careful. <<>> In the trade this is called a sub panel. It is a complicated job in as much as you have to know wire sizes, ampacity of wires and proper electrical workmanship. Such a project should be left to a licensed electrical contractor to take out the proper permits and call for proper inspections. By taking this route it will leave you confident that if any mishaps happen to the installation down the road your insurance company will be behind you 100%.

Related questions

A 60 amp electrical service panel at a 2700 square foot home would be?

Too small.


Would a 125 amp service panel be enough for a 1900 square foot house?

Absolutely not. A 60 amp whole house service is totally insufficient to power todays home, especially a 2800 square foot house. The NEC (National Electric Code) requires a minimum of 100 amp electrical service to any single family residence.


Why would the volts increase from the main panel to the sub panel?

Check the battery voltage on your tester. The voltage on the panel is the same throughout the whole electrical system.


What is the need for electrical shutdown?

You would need to shutdown the power whenever you are working on the electrical service.


When would you want to upgrade the main electrical panel vs just adding a sub-panel?

Depending on how many breakers you have in your exisiting panel if you only have a old 6 or 8 circuit panel then I would suggest a new panel, In the newer building world where you have a 20 or 30 circuit panel then I would suggest a sub panel.


Can electrical panel be hung by conduit?

A bad idea. That would be against the electrical code and the manufactures specifications.Another answer:Agreed. Only use approved structural material to hang an electrical panel. If you need to hang it away from an existing wall, use Unistrut.


What is electrical rating s o?

If you are referring to electrical cord that would be, Service grade Oil resistant


What would cause a loss of a phase in a 3-phase electrical supply panel connected to a refrigeration system?

You have to follow the lines. Could be blown fuse or any number of other things. Follow it back to the service.


What would you use to check an electrical panel for loose connections and excessive heat?

infrared thermal camera


How do you check electrical panel?

That depends on what you're trying to find.If there is NO power to the panel, you would put a volt meter across the lugs entering the panel or tighten the lugs holding the service cable.If one circuit is failing, you might want to remove the breaker and verify that it isn't arcing at the rail, or you might want to replace the breaker.If you simply want to check to see if there IS an electrical panel, just search for it; it's usually not too far from the meter base.As usual, if you don't understand electricity, the dangers of electricity and the proper wiring standards and practices, leave it alone and request that an electrical contractor perform the work for you!


How much energy does a 213 TV need from a solar panel?

The same amount it would need from your electrical supplier.


Does a floor drain in front of an electrical panel infringe on the dedicated space?

I really do not see how this would be an infringement on the panel space and from a safety standpoint I see no problem with it. Of course I would not want to touch the panel if the floor was wet even though it would be no real safety issue if the panel was wired correctly. Just use common sense.