Q: Blower will not blow fuse is good?
Write your answer...
Submit
Related questions

When you turn the ac blower on your 96 Nissan maxima the fan does not blow at any speed but you can hear the ac compressor kicking in?

check the blower fuse if the fuse is good the blower motor is bad or else you have short


1996 ply neon will a bad blower snap the fuse?

Yes!! it will snap a fuse...if the blower is seized up or shorted out, it will blow the fuse to avoid damaging your car!!


If defective blower motor draws more current than a good motor because?

defective motor will not run, also cause the blower motor speed resistor to burn out and eventually blow the fuse. a motor with defective bearings will draw excessive current causing either the fuse to blow or cause the motor to overheat


What could be wrong if the AC blower on a 1995 Ford Windstar will not blow air?

fuse, wiring, blower motor, blower motor switch, blower motor resistor


When the heater is on you feel heat but will not blow?

Defective blower motor, blown fuse, or a defective Blower Motor Resistor Pack.


Why will the blower motor not blow on a 2000 grand marquis when ive already replaced the resister climate control head and the fan is good?

Fuse is blown.


What could be wrong with 1991 Continental when no air will blow and the Fuse and blower motor are good?

There is no power go to the motor. Test the wires to see if there is power to it.


Fan blower on 1983 Mercedes Benz causes fuse to get hot what the problem?

If the blower runs on high it will get hot. If the blower is wearing out this will cause it to get to hot and blow.


Your ac want blow how do you fix it?

If you are saying the blower motor will not work, then check the fuse. If the fuse is not blown, then it is possibly a defective Blower Motor Resistor Pack, blower motor, or blower motor speed control switch, in that order.If you are saying the blower motor will not work, then check the fuse. If the fuse is not blown, then it is possibly a defective Blower Motor Resistor Pack, blower motor, or blower motor speed control switch, in that order.


Why would a 10 amp fuse that controls the blower relay switch on a 2002 Ford Ranger Edge continue to blow on a regular basis?

Bad ground or short. Check to make sure a smaller than required fuse has not been installed. Use to correct fuse, no smaller or larger. Blower motor can also be going bad causing it to blow a fuse.


Why won't my air conditioner blow air?

Check all of the following..... 1. The blower fuse. 2. The blower ground and power. 3. The a/c controller. 4. The blower resister. 5. The blower motor itself............


Why would the fan control on any speed not blow air The heater blower motor is ok for a Honda Civic?

If you know the fan motor is good but it will not work, first check the fuse. If the fuse is good, then it is either the fan motor switch or the resistor pack that is defective.


94 silhouette will not blow air after having replaced blower motor fan and blower motor resistor. What could be wrong?

Blown fuse? Bad switch?


What will cause your ac and heater to stop working it do not even blow?

Blown fuse, bad heater blower motor control switch, bad blower motor, or a bad blower motor resistor pack.


Why doesn't my 2004 MITSUBISHI ENDEAVOR air conditioner blow air out?

If the blower isn't working, start with the easy first. Get out owner's manual and find all the fuse locations. Check which fuse controls the blower and then check the fuse.If there is no fuse for the blower, then you need a professional tech to test it. It could be the blower motor, a relay, a blower resistor, the blower switch or the wiring between any two or more of those components.If the blower motor is out in the open, you could try LIGHTLY tapping on it with the handle of a screwdriver. If the blower starts working right as you do that, then you have a bad blower motor.


Why would your 95 ford contour have heat coming out but doesnt blow it for the AC or heater?

Bad blower motor? Blown blower motor fuse? Bad fan switch? Bad blower resistor pack?


Why does the blower motor fuse blow?

Your blower motor could be bad or it could be covered in so much dust that the motor is straining to turn the fan (picture a ceiling fan with the blades covered in dust on the air cut Sid which affects the ability of the fan to blow air and makes the motor work harder.) If the fuse blows immediately upon turning your fan on, there may be a short circuit in one of the wires to the blower motor or blower motor resistor (which controls the speed of the blower motor or you could be using a fuse with too little amperage. Consult your owners manual or the diagram in the fuse panel/box cover for the correct amperage for each fuse. If the fuse's amps are too small it will blow fast because it can't handle the amps going through it. If the fuse's amps are too high, the fuse won't blow when it's supposed to so it will cause damage in your electrical system. Fuses are meant to blow when something goes wrong in your electrical system to keep the rest of the system safe until you solve the reason why the fuse blew. Hope that helps!


Defrost on 98 contour wont blow?

Check for a blown fuse. If fuse is good remove blower and check for power at the blower motor plug using a multimeter or voltage tester. If power is available replace the blower motor. If power is not available you can do a running check by directly hooking up a 12 vdc power supply to the blower to see if it will even run. If the blower runs, your problem is your most likely the fan speed control resistor which will need to be replaced or repaired.


Why doesn't the air blow in a 1999 Oldsmobile Alero?

Blown blower motor fuse? Bad blower motor or resistor? Check to see if you are getting power to motor - if so motor is bad if not check fuse and/or resistor Bad switch?


Why doesn't your car ac blow any air?

Something with the blower motor. It may be as simple as a bad fuse, or it may involve wiring or even the blower motor itself.


What might cause fuses to blow when the AC is on in a 1998 Buick Skylark?

Likely the blower motor is bad, causing increased current and blowing the fuse. Replace the blower motor.


Blower doesn't work on 1994 gmc sierra. Where do I start to try to fix it?

Start by checking the fuse. If the fuse is good, apply 12 volts directly to the blower motor. If the motor runs it is good. Check all the wiring for loose or burnt wires. If all this checks out, then the Blower Motor Resistor Pack may be defective, or the blower motor speed switch itself.Start by checking the fuse. If the fuse is good, apply 12 volts directly to the blower motor. If the motor runs it is good. Check all the wiring for loose or burnt wires. If all this checks out, then the Blower Motor Resistor Pack may be defective, or the blower motor speed switch itself.


Your car will not blow air?

the blower motor not getting power blown fuse or thermal switch or motor just went out


Why won't my car blow air?

If the blower motor does not function, it is blown fuse, defective blower motor, defective blower motor resistor pack, or in rare instances a defective blower motor speed control switch. Check the fuse. If it is OK, apply 12 volts directly to the blower motor and if it runs, you probably have a defective Resistor Pack. Very common problem. The only fix is to replace it.


Where is the blower motor fuse in a 1993 ford escort?

The blower motor fuse is in the passenger compartment fuse panel underneath the dash on the driver's side. The blower motor fuse is a 30 amp fuse marked BLOWER.