To whom it may concern, Did you mean to ask what is static electricity?? If so the term static, which means stays the same, means the electricity in a circuit is static; it does not change direction and electrons only have 1 path to travel. An example of a static circuit would be a DC ( Direct Current) circuit, whereas an AC circuit; alternating current, alternates between 120v to 0v, then 0 to negative 120, back to 0v, then to positive 120v, however, this happens at so fast you would never catch a reading on a multi meter.
You can have only one current carrying conductor in a conduit, but that conduit must have a slot to relieve the eddy currents that will be created by the transformer effect created by the conductor. It is better to run the neutral or opposite conductor along with the hot conductor together in the same conduit, or through the same penetration, so as to minimize this effect.
Yes, as long as the amp rating is the same. Examples, 600v 100amp fuse can be used in a 120v 100 amp's location.
3 OR 4 . you only need 2 wires for 220, 1 phase is 120v between 2 of them its 220v . you also should have a ground for the third wire ,and the newer stuff requires a neutral or white wire for the 4th wire. hope i helped , D
The conductors of any three phase circuit must be run in the same conduit. If the circuit requires a neutral, it must also run with the conductors in the same conduit. (If they were to be run in more than one conduit or raceway, the circuit would not operate properly.)
YES
According to the wording ,2 different phase wires "can" run through the same conduit. Not only can they, but if they are part of the same circuit they must. And in cases where conductors are paralleled, meaning more than one conductor per phase as is common in commercial and industrial installations, you put one conductor of each phase and a neutral, if one exists, and a ground in each conduit. Not doing so, meaning to put all of one phase in one conduit, causes a voltage to be induced into the conduit and a tremendous amount of heat builds up. Even when using pvc or other non-metallic conduit, somewhere along the way you have something metallic and have the same problem. To simplify, you must put all conductors associated with the same circuit in the same conduit.
The simple answer to your question is yes. But there are limits to how many wires can be in any conduit, and the current carrying capacity of the conductors can be affected by distance, ambient temperature, and how many conductors are contained in the same conduit. Other things to consider are, Can you physically fit the wires in there? Would it be easier to run a new conduit? Do you have the manpower necessary to get the work done?
No, the conduit has to be supported individually from a supportive structure. The spacing of the strapping is related to the size of the conduit.
Yes, 120 and 240 volts can be run in the same conduit.
no 208v is bigger
No
Back set for all conduit sizes is not the same. The greater the diameter of the conduit the length of back set increases. Without the diameter size of the conduit, an answer can not be given.
The same as in any other circuit - in the case of a parallel circuit, the switch will either allow or not allow current to pass through one particular branch.
In the US, the National Electrical Code (NEC) will allow you to install single phase and three phase systems in the same conduit.
No you can not mix voltages. That being said if the lower voltage is part of the control circuit from a MCC control centre then yes they can be mixed as the low voltage control is part of the complete system.Composite power & control Teck 90 cable has the power feeders and usually 3/#12 or 3/#14 wires embedded in the same cable. These three wires allow for remote stop - start controls to be mounted neat the motor out in the field.