No problem. But watch the wattage on the bulbs. The heat is going to go the opposite direction. And the lamp is ment to be in the opposite stress position so that it could be much less stable than when sitting. But wiring wise it is the same, just wire the two wires in the ceiling to the two on the lamp. And there may be issues with code requirements. Overall it is better to be safe than sorry and use a lamp designed for the ceiling.
eHow is a great resource for topics like this, with articles like "How to Re-Wire a Lamp," "How to Rewire a Lamp with a Rotary Switch," "How to Rewire an Old Lamp," and "How to Wire a Floor Lamp."
You need to learn how to use a volt-ohm meter or hire an electrician. If the wire were hot you could have been injured.
You can use a 3-prong to 2-prong adapter and connect the lamp's ground wire to the screw on the metal cover plate of the ungrounded outlet. This provides some level of protection by grounding the lamp. However, it's recommended to consult with a professional electrician for a safer solution.
To rewire a lamp socket, first unplug the lamp and remove the bulb and shade. Then, unscrew the socket from the lamp base and disconnect the old wires. Cut new wires to the same length and strip the ends. Connect the new wires to the corresponding terminals on the socket, usually labeled "hot" and "neutral." Secure the wires with screws or by twisting them together. Finally, reassemble the socket and test the lamp to ensure it is working properly.
To rewire a 220V lamp for 120V, you will need to replace the existing 220V bulb with a 120V bulb that is compatible with the lamp's socket. Next, you will need to install a 120V compatible power cord that matches the voltage requirements of the lamp. It's important to refer to the lamp's manual or consult with a professional electrician to ensure the rewiring is done correctly and safely.
what the function of lamp holder
To securely attach a lamp to a ceiling using a threaded rod, first, drill a hole in the ceiling that is the same diameter as the threaded rod. Insert the threaded rod through the hole in the ceiling and secure it with a nut and washer on both sides of the ceiling. Then, attach the lamp to the threaded rod using appropriate hardware. Make sure the lamp is securely fastened to the threaded rod to prevent it from falling.
The force responsible for holding up a lamp hanging from the ceiling is called tension force.
To rewire a lamp socket safely and effectively, first unplug the lamp and remove the bulb and shade. Use a screwdriver to loosen the screws holding the socket in place. Disconnect the wires from the old socket and remove it. Cut and strip the wires, then attach them to the new socket following the manufacturer's instructions. Secure the new socket in place and reassemble the lamp. Test it to ensure it is working properly before using it again.
Door (front door)
you need a transformer (instead of rewiring) from 220v to 110v The above answer will work but it is not correct. All lighting fixtures installed in Canada have to be CSA certified. If you really like the design of the lamp then you could consider rewiring it with certified CSA components You can buy replacement lamp parts at any DIY outlet. Change out the lamp cord and plug end along with the lamp (bulb) holder and you will have a certified fixture.
To safely and effectively rewire a lamp socket, first unplug the lamp and remove the bulb. Then, carefully remove the socket cover and disconnect the old wires. Next, strip the insulation from the new wires and connect them to the corresponding terminals on the socket. Make sure the connections are secure and insulated. Finally, reassemble the socket, plug in the lamp, and test it to ensure it is working properly. If you are unsure or uncomfortable with this process, it is recommended to seek the help of a professional electrician.