Q: Can a neutral conductor be uninsulated?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What does a hot terminal do?

A 'hot' terminal is a slang expression for the line terminal of an AC supply. In Europe, for example, a single phase supply to a building has three conductors: line conductor, neutral conductor, and protective (earth) conductor. The line conductor has a potential of 230 V with respect to the neutral; the neutral conductor is at approximately the same potential as the earth conductor. In North America, there are two line conductors, which are at 240 V with respect to each other, and at 120 V with respect to the neutral.


Why you need neutral conductor?

To complete the circuit. The word neutral is a convention it does not mean it has no purpose


Can a neutral conductor be broke in a disconnect?

The neutral can be broken in some installations. One example is when wiring explosion proof equipment.


What is an AC single phase 2 wire system?

two wires coming off the secondary of the transformer ex. residential voltage of 120 volts each line, and one neutral wire, L1 to neutral is 120 volts, L2 to neutral is 120 volts, L1 to L2 is 240 volts.AnswerA single-phase, two-wire, system comprises a line conductor and a neutral conductor. In European countries, the line conductor for a residential supply is at a nominal potential of 230 V with respect to the neutral.In North America, a 'split phase' system is used for residential supplies; this is a single-phase, three-wire, system comprising two line conductors which and a neutral conductor. The nominal potential difference between the line conductor is 240 V, while the potential of each line conductor with respect to the neutral is 120 V.


Why link is provided as neutral in an ac circuit?

link is provided in neutral path of ac supply because it should provide a path for unbalanced currents , if we use fuse ,fuse may blow of and damage the entire system and also unbalanced currents may be more than the fuse rating

Related questions

How does a man get an electric shock?

By touching an uninsulated conductor which is under electrical tension.


For nonmetallic-sheathed cable may the uninsulated conductor be used for purposes other than grounding?

no


What is the purpose of neutral contactor?

Presumably, you are asking the purpose of a neutral conductor, rather than 'contactor'?A alternating-current supply has two conductors, a lineconductor and a neutral conductor. The line conductor is at system potential (e.g. 230 V in Europe), whereas the neutral conductor is at approximately earth (ground) potential because it is earthed (grounded) at the supply transformer. The neutral conductor acts as the 'return' path to the transformer, carrying the same load current as the line conductor.


What two colors may be used for the ground conductor neutral?

What two colors may be used for the ground conductor (neutral)


How are voltages imported into installations through the supply neutral conductor?

A 'voltage' is another name for a potential difference. As the name implies, a potential difference exists between two different points or, in the case of an electrical installation, between the line conductor and the neutral conductor. So the neutral does not 'import voltages'. Voltages exist between the line (hot) conductor and the neutral conductor.


What are the property of good conductor?

a good conductor should be electrically neutral.


What type of circuit is it that has a hot conductor contacting a neutral conductor?

A shorted circuit.


What is the difference between a neutral wire and a hot wire?

In alternating-current systems, we don't have a 'positive' and a neutral conductor, but a 'line' and a neutral conductor.The neutral conductor is connected to the earth and, so, has a potential of approximately zero volts.The line conductor, on the other hand has a potential of approximately 230 V (in Europe) or 120 V (in North America) with respect to the neutral conductor. For this reason, line conductors are frequently referred to as being the 'hot' conductor.


What is meant by PEN conductor when referring to earthing of supply system?

Conductor combining the functions of both a protective earthing conductor and a neutral conductor


What does a hot terminal do?

A 'hot' terminal is a slang expression for the line terminal of an AC supply. In Europe, for example, a single phase supply to a building has three conductors: line conductor, neutral conductor, and protective (earth) conductor. The line conductor has a potential of 230 V with respect to the neutral; the neutral conductor is at approximately the same potential as the earth conductor. In North America, there are two line conductors, which are at 240 V with respect to each other, and at 120 V with respect to the neutral.


What color are the phase neutral and earth cores in flexible cords?

It depends on the electrical standards of the country in which you live. In Europe, for example, the line conductor(not 'phase conductor'!) is brown, the neutral conductor is blue, and the earth conductor* is green/yellow stripe.[*properly called a 'protective conductor']


Why you need neutral conductor?

To complete the circuit. The word neutral is a convention it does not mean it has no purpose