Romex NM. Is the most widely used electrical wire in homes.
Romex, All you have to do is go to a hardware store and tell them you need house wire. It comes in a box. I am not sure how many feet. If you are just looking for the gauge, they will know that too.
The exact year that Romex Wire came out is not listed on their website. However, they do say that they have been selling the wire for over 88 years. I have found the year 1926
Romex is a manufacturer's wire cable trade name, the 10 refers to the size of the wire inside the cable set. A #10 AWG copper conductor with an insulation factor of 90 degrees C is rated for 30 amps.
They can as they will support the wire into the box. The deciding factor should be the cost. A BX connector costs about four times the price of a romex connector. Also to keep in mind is that most junction boxes these days have their own built in clamps.
No, you can feed it with a 2 wire Romex + ground. It depends on what is mounted on the ceiling. If it is just a light all you need is 2 wire + ground Romex. However if it is a fan/light and you want to control each one independant of the other you will need to use 3 wire Romex + ground. This is of course if you have 2 seperate switches. You would then connect the red wire to the blue light wire and the black wire to the black fan wire. If you use 2 wire Romex just connect the blue and black fan/light wire to the black wire in the ceiling box.
Romex NM. Is the most widely used electrical wire in homes.
Romex, All you have to do is go to a hardware store and tell them you need house wire. It comes in a box. I am not sure how many feet. If you are just looking for the gauge, they will know that too.
What kind of wire? If it's a power wire, why is the place wired with conduit? Commercial buildings must put all power wiring in conduit, so if you're planning to run romex in a commercial building, the answer would be "no", it's not permissible. If it's data wire, note that there may be some "crossover" interference if the data wire follows a power wire for very much distance. It's usually not a problem to cross a conduit and tie to it, but it's generally recommended that you not tie data cable to conduit.
The exact year that Romex Wire came out is not listed on their website. However, they do say that they have been selling the wire for over 88 years. I have found the year 1926
No, do not mix aluminum wire with copper wire.
Romex is a manufacturer's wire cable trade name, the 10 refers to the size of the wire inside the cable set. A #10 AWG copper conductor with an insulation factor of 90 degrees C is rated for 30 amps.
They can as they will support the wire into the box. The deciding factor should be the cost. A BX connector costs about four times the price of a romex connector. Also to keep in mind is that most junction boxes these days have their own built in clamps.
The key is that you don't want to cause over-heating in wire. The answer is you can probably do what you want unless it involves high current and a small cross section in wire mold such that the Romex could generate too much heat. You could always strip out the wires inside the Romex and just run them in the wire mold.
Standard Romex is a three-strand, solid core wire, individually insulated, in a common sheath to make it easier to pull. For a short time, some manufacturers were making romex with aluminum because the cost of copper was so high, but the aluminum wire was not as good as the copper, and the practice was discontinued.
Household wire called romex has ground, neutral and hot wires.
If the wire is to be buried you'll need to use "direct burial" wire; if you're staying inside the house, just under the floor and above the concrete or dirt, standard romex should be fine.