Yes, as long as the rating of the breaker is high enough. Do not use a 20 amp breaker with 14 ga wire however. 14 ga wire can not have a breaker ratered high than 15 amps serving it.
Something wrong with it like a bad motor.
Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.
Check the MFG for the amps it uses, if it is suppose to be on a regular 20amp line, then replace the breaker with a 20amp breaker. With the 30amp breaker,it will work, but if there is a surge, you could send too much power to the appliance and fry it. Most refrigerators, are just on a regular 120v household outlet. Besides a 30amp breaker must have 10ga wire, if the wire is 12ga,it can not be attached to a 30amp breaker.
If you can reset it, then it is not a fuse it is a breaker. You use then so you do not have to replace a fuse, you can just reset the breaker.
A GE tandem breaker can be removed and replaced with a GE single pole breaker.
Not unless the wire going to the refrigerator outlet is AWG 10/2. If it is wired with 12/2 wire then you must use a 20 amp breaker. Using a 30 amp breaker is dangerous and a fire hazard.
The load current is greater that the amperage of the breaker. Add up everything that is plugged into the circuit. If the total is greater that the number marked on the handle of the breaker unplug some of the equipment.
For a standard size refrigerator, a dedicated 15 amp circuit is used.
The most likely possibility is the refrigerator has a problem and needs to be fixed. Another possibility is the refrigerator is on a circuit that does not have enough current capacity to operate it and other appliances that are on the same circuit.
Something wrong with it like a bad motor.
They use their own network, Skinny Network.
A breaker switch is easier to use.
Use a 30 amp breaker.
It is mounted to the back of the breaker panel that is below the refrigerator.
Everything they use a regular refrigerator for. Subzero is a type of refrigerator, but it is also a brand of refrigerator. They are basically what they sound like, a refrigerator/freezer that reaches and hold subzero temperatures.
Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.
The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.