Rephrase your question. As it stands, it makes no sense.
You can take three separate single-phase circuits from a 3-ph generator. Just use one of the live wires plus the neutral to make a single-phase supply. <<>> A three phase generator does not have to be converted to single phase. In electrical terminology any two legs from a three phase system are classed as single phase. No matter what voltage the generator is producing, L1 - L2, L2 - L3, L3 - L1 are classed as single phase legs along with L1 - N, L2 - N, L3 - N. If the generator output voltage is not the voltage that you are looking for use any two legs of the generators output voltage and use a transformer to obtain the voltage that you need.
yes we can by using one phase and neutral line
Yes, you can use three single phase transformers on three phase applications and interconnect them to serve as a single transformer or you could use one single phase transformer fed from two of the three lines in a step down application.
the necesscity of two three phase transformers operating in parallel are as follows...if the one transformer fails to give supply,then another transformer can be used in parallel and hance,continuity of supply can be maintained.one transformer can be easily take out from the supply for repair & maintanance.if the load on the substation increases beyond the rated values of transformer, then another transformer can be used to share rhe load of the substation.
No, you can not get three phase power from a single phase generator no matter what internal connections you use. On the other hand you can obtain a single phase supply from a three phase generator by using any two phase legs as a source. <<>> I single phase generator can produce three phase by using a converter but its not efficient and does not work very well. <<>> Well there is an another way too. but one has to be precautious in that...simply short the three phases of the electricity supply n feed them with a single phase of the generator...now when the mains is bak make sure the short phases are separated again and then powered up otherwise you will be hearin blasts here n there...use ATS for automatic switching that gives you automatic transfer and can be programmed when to short and when not to..
No, you can not get three phase power from a single phase generator no matter what internal connections you use. On the other hand you can obtain a single phase supply from a three phase generator by using any two phase legs as a source. <<>> I single phase generator can produce three phase by using a converter but its not efficient and does not work very well. <<>> Well there is an another way too. but one has to be precautious in that...simply short the three phases of the electricity supply n feed them with a single phase of the generator...now when the mains is bak make sure the short phases are separated again and then powered up otherwise you will be hearin blasts here n there...use ATS for automatic switching that gives you automatic transfer and can be programmed when to short and when not to..
220 volt single phase from 480 volt 3 phase that one wire taken one phase and second wire connected in earth point. we get 220 v The above answer is incorrect, one phase from a three phase 480 volt system will give you 277 volts to ground. You must use a transformer to get the voltage you need.
To answer this question a voltage must be given to find the current output. Also whether the generator is three phase or single phase.
If the primary and the secondary windings of the three phase transformer are connected in delta, you cannot get a healthy neutral from it but why bother? You simply drive a rod into earth and use it as a neutral. Alternatively either the primary or the secondary windings must be connected as star and you use the common point as neutral.
If the generator is a 12 lead reconnectable, you can use something called a zig-zag connection.Check the link below. It is an installation manual for a Marathon generator. Zig-zag connections are shown on page 8. For a home, you would use the low zig-zag connection for 120/240V (in the US). One caveat: you can only load a zig-zag single-phase connected generator to a maximum of 66% of its rated load. So, a 15kW 3-phase generator would only provide 10kW single-phase power. If this doesn't quite make sense, hire a pro!IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS. If you do this work yourself, always turn off the power at the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicatorto insure the circuit is, in fact, de-energized.
I'm not sure I understand the question. If you are asking if it's single or 3 phase, this will be marked on the name plate.
A single phase power supply has two "hot" legs or conductors which have a sine wave that are 180 degrees apart. A three phase power supply has three "hot" conductors which have a sine wave that are 120 degrees apart. You can thank Nicoli Tesla, whose birthday is today for the three phase or polyphase power supply and of course all alternating current!