yes
Reverse any two line leads connected to the motor will reverse the directional rotation of the motor
There are two alternate methods depending on whether the motor is single phase or three phase. On a single phase motor, reverse either the start winding coil lead or the run winding coil lead but not both. This action will reverse the motor's rotation. On a three phase motor, interchanging any two of the three coil leads will reverse the motor's rotation.
No. If the motor runs backwards, swap any two phases to reverse the rotation, like this: Old wiring: phase A - brown wire - motor lead T1 phase B - yellow wire - motor lead T2 phase C - orange wire - motor lead T3 New wiring: phase A - brown wire - motor lead T2 phase B - yellow wire - motor lead T1 phase C - orange wire - motor lead T3
I think the resistance value of starting winding is less than the running winding of the single phase motor
A single phase induction motor has two sets of coils and a centrifugal start switch. The start winding is in series with the start switch. The start winding provides a rotating magnetic field in one direction enabling the motor to start. The motor can be reversed by reversing the connections of either the start winding or the run winding but not both.
If a three phase motor in running in reverse, then one of the phases is reversed, plain and simple. If the wiring is correct at the motor, perhaps the phase reversal occurred someplace else.
Reverse any two line leads connected to the motor will reverse the directional rotation of the motor
Reverse any two line leads connected to the motor will reverse the directional rotation of the motor
There are two alternate methods depending on whether the motor is single phase or three phase. On a single phase motor, reverse either the start winding coil lead or the run winding coil lead but not both. This action will reverse the motor's rotation. On a three phase motor, interchanging any two of the three coil leads will reverse the motor's rotation.
Then it is not a three phase motor.
three-phase motor: Swap the connections of any two phases to the motor.single-phase motor: Usually this can be achieved by reconnecting the starting capacitor from one motor winding to another.Another AnswerAs you have no access to the motor's phases, you must interchange any two of the three line conductors.
3 phase reverse relay can be utilized to control 480V motor 60HZ for controlling their speedspeed.
reverse wires
how reversing an ac single phase induction motor to wark as induction generator
This question doesn't really make any sense - any of the two phase? A three phase induction motor requires 3 phases to start - if a single phase is lost while the motor is already running then yes the motor will continue to run. A three phase motor will not start if it is missing a phase.
If you mean to reverse the direction of a three phase motor, you just switch any 2 leads. switch 1 and 2, or 2 and 3, or 3 and 1.
The reverse of condensation is evaporation or vaporization.