Washing machines in the U.S. operate on 120 volts. That requires a single pole 20 amp breaker and wired with 12/2 w-ground wire. Black to the breaker, white to the neutral bus bar, and copper ground to the ground bus bar.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Do you need a 20 amp single or double pole breaker for your washer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Have existing a 125 amp main need more breakers spaces?

You can swap a single breaker for two mini breakers or you can add a sub-panel. If you only need a couple of extra circuits then just add mini-breakers.


Do you need a gfci outlet if you have a gfci breaker?

Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.


Does a whirlpool tub need its own cuircit breaker?

Yes.


Why do you need a 125 amp breaker for a 83 amp furnace?

If you put a 85 amp breaker in there it will overheat from the starting and stopping of the motor. The extra size of the breaker insures that the furnace will run without interruption and without overheating the breaker. And electric motor can draw three times the amperage rated on start up momentarily. This is why there is need of extra amperage ratings.


What is a 30 amp circuit breaker used for?

A 30 amp circuit breaker is needed unless the load is a motor circuit, then it has to be sized to 250 percent of the motors full load amps. For 30A circuit is needed breaker 30*1.25=37.5 --> 40A. If load is lamp or heater, then use breaker of group A or B. If load is motor, then use breaker of groupC or D (very hard start) or special safe breaker for motor - with variable amp setpoint. See related link also. By code you are only allowed 80% of the rating of a breaker. So 30x80%=24amps. 24 amps is the MAX allowed on a 30 amp breaker. You would need a 40amp breaker for a 30 amp circuit. 40x80%=32. So you would want a double pole 40amp breaker.

Related questions

Can you use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner?

If the 12,000 BTU A/C only requires 20 amps to run then yes you can use the same 12 gauge wire but you cannot change it to a 15 amp breaker. You will need to install a 20 amp double pole breaker. If it requires more than 20 amps you will have to replace the wiring and breaker.


Why dish washer does not work?

Well , you need to give us SOME clue. -Is breaker on, is power at box on front of washer, do any lights come on. - -


Do you need to use some type of mini breaker panel with a single 15A circuit breaker to connect a 15A receptacle into a 30A line?

To be short...Yes


Why do you need a double 30A pole for an electric dryer if you only have one pole left in your box?

The dryer is 220VAC. You need a double pole breaker to get 220 out of a home breaker panel. Perhaps you should contact an electrician who understands wiring so that you don't burn your house down.


Can a double pole 15 amp breaker help?

No. In North America a double pole breaker is used to obtain a voltage of 240 volts from the distribution panel. What ever the amperage rating stamped on the handle of the breaker is, that is the amperage that the breaker will trip at.


Have 30 amp double pole need 15 amp 120v?

Remove the 30 amp double pole breaker and install at least one single pole 15 amp breaker. It is best if the other slot is not left open so if you have another single pole breaker of any size install it in the 2nd spot so it isn't open when you replace the cover on the panel. For your 15 amp circuit you need #14 gauge copper wire or larger with a hot, neutral, and ground. Your 30 amp circuit was probably wired with #10 gauge conductors. These will probably work on your 15 amp circuit but it may be difficult to connect #10 conductors to devices.


Have a 240v 36a pressure washer to install electric on what gfci process do you need?

This is really a heavy duty application and you are going to have to go to your main panel. I suggest a 50A GFCI breaker. It would likely run to a heavy duty outdoor outlet with a possible disconnect. This will require 6 AWG copper wire. You could likely get by with 40A breaker and 8 AWG, but of concern is the surges that happen when operating a pressure washer.


Why do you convert 120v circuits to 220v circuits?

You would need to change a circuits voltage if your adding a load that requires 220 when the present circuit supplies 120. If you need to do so it's pretty simple! First purchase a double pole breaker at the proper amp rating. Next find the breaker in the panel that supplies power to the circuit you wish to change to 220. Turn off the breaker and pull it out. Find the neutral for that circuit. Then double check and make sure it's the right neutral. Then check one more time. Now take the neutral and the hot wire for that circuit and connect them to the double pole breaker. install the breaker into the panel and turn it on. If you connected the right neutral you'll have 220 on that circuit. If you didn't you'll know because you'll trip the breaker.


Can you use a 2 pole breaker for a 120 volt single phase circuit?

A single phase circuit uses a 2 pole breaker if the circuit is 120/240 split phase and the load is connected 240. Both legs are hot, so both need to be protected. This is the normal US/Canada configuration.


What size breaker do you need for 9000W at 440V 3 phase delta?

50amp but if considering the breaker cannot withstand starting current you need to size the breaker up.


What Size breaker for 6 gauge wire?

You need a 60 amp breaker.


Can you install a tandem breaker?

Tandem breakers, often called split breakers or double breakers, provide two separate circuits in the space of a regular sized breaker opening. Every circuit breaker panel has a limited number of circuit openings available. The problem is that when the openings are all used up and you still need to add another circuit, what do you do? You could change the electrical panel or double up circuits on a breaker, but this could place too much load on a particular circuit. So what then? The answer that many have found is a tandem breaker. This type breaker is the same size as any other breaker, but it has its difference. This breaker sports two smaller breakers built into one regular sized breaker. Each has its own breaker switch and the breaker snaps in just like a regular breaker. With this simple innovation, you can add a circuit and protect the circuit on its own dedicated line.