answersLogoWhite

0


Best Answer

Every bathroom should have its own dedicated 20 amp electrical service breaker. The electrical service breaker should have a surge protector in the case that something electrical falls into water.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

12y ago

The receptacle in the bathroom must be on it's own 20 amp circuit, no other loads can be on it.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Does a bathroom require it's own dedicated 20 amp breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What size amp circuit breaker would protect a 12kW boiler?

The breaker protects the wiring not the boiler. 12,000 watts at 240 volts will require 50 amps. So, you will need a 60 amp breaker using AWG# 6 wire on a dedicated circuit.


Can the power to your whirlpool be on the same 20 amp circuit as the bathroom lights and outlets?

No, the whirlpool has a motor load connected to it and should be connected to a dedicated ground fault breaker.


What circuit is a microwave?

A dedicated 20 Amp circuit wired with 12/2 wiring an a 20 amp breaker.


Can you wire a 120 volt 7 amp Jacuzzi motor to a wall outlet in my bathroom?

No, it must be on a dedicated circuit of it's own. It must be on AWG 12/2 wire with 20 amp breaker. It also must be protected with a GFCI outlet.


What size breaker for?

For a standard size refrigerator, a dedicated 15 amp circuit is used.


What size circuit breaker should be used for dishwasher and disposal?

A 15 amp dedicated circuit breaker should be used for the dishwasher. The disposal can be wired to the general kitchen 15 amp circuit.


Can 50 Amp breaker replace 45 Amp breaker?

Both a 45 amp and 50 amp breaker would require 6 AWG wire. So if you have 6 AWG wire and any devices like an outlet are rated at 50 amps or greater you are okay.


What size wire and breaker do you need for a 5000 watt garage heater?

Look on the heater and see what amps it is pulling. That will determine the wire size and breaker size. It must be on a dedicated circuit. 15 amps = AWG # 14 wire with 15 amp breaker 20 amps = AWG # 12 wire with 20 amp breaker 30 amps = AWG # 10 wire with 30 amp breaker 40 amps = AWG # 8 wire with 40 amp breaker


Can you use a 20 amp circuit breaker for an electric dryer?

If you are referring to a cloths dryer, the answer depends on the requirements of the dryer. Most dryers require AWG#10 wire with a 30 amp fuse. If the wiring is AWG#12 then use a 20 amp breaker but never use it on AWG#10 which requires a 30 amp breaker. If you are referring to a hair dryer then yes a 20 amp breaker is fine.


What size breaker should be used for 1500 watt bathroom exhaust fan heater?

20 amp breaker 12 gauge wire assuming its 120 volt


What are the standard size circuit breaker amperages?

In North America the standard sizes for breakers are 15, 20, 30, and 40 amps. The 15 amp size breaker is used in general circuit wiring. The 20 amp size breaker is used for dedicated appliance receptacles, hot water tank and baseboard heating. The 30 amp size breaker is used for a clothes dryer. The 40 amp size breaker is used for the electric range.


Can an electric range be powered from the same circuit as an electric dyer?

No. The two appliances usually have dedicated circuits. The range will have a two pole 40 amp breaker and be fed with a 3-C #8 copper cable. The dryer will have a 30 amp two pole breaker and be fed with a 3-C # 10 copper cable. As you can see by powering a 40 amp device from a 30 amp breaker, full operation of the range will trip the 30 amp breaker.