Turning the breaker on allows the power to flow through to the outlets, lights, and appliances on that circuit, so yes power goes to and through a turned on breaker. If the breaker is off, but the main power is on, power still get to the breaker, usually from the bus bar that runs down the middle of the back of the breaker box.
If a single pole switch is wired to be a master switch, the switch would have to be in the on position for any other control devices to operate. Turning the master switch off would eliminate power to all devices (and/or loads) which it was serving. For example, some homes have a switch to control their outside light. If the outside light has a photo eye (the light will only come on at night), the switch is the master switch. Another example would be the breakers in an electrical panel. Each breaker would be the "master switch" for the circuit it protects. The main breaker in the panel would be the "master switch" for the entire home.
The breaker will have a black wire connected to it. Turn off the main breaker and then disconnect that black wire from the breaker. The breaker will snap into the main bar. Remove the breaker and install the new one. Reconnect the black wire to the breaker and then install the cover and turn the main breaker back on.
No, it is still live even when the switch is open...
The biggest circuit breaker in any home is the main breaker located in your main breaker panel that is installed where your electrical service cable comes into your home.
Switch your main breaker off.
The rating of the main switch is decided upon by the current incoming mains. The main switch can't be lower than the incoming. In order to upgrade the main switch, the breaker box will need a complete upgrade.
The voltage before the breaker is from the distribution panel's buss bars. This voltage is controlled by the panel's main breaker. To have no voltage on the terminal of the breaker means that either the breaker is shut off or it has gone into a trip position. If it has tripped push the handle of the breaker to the off position and then to the on position. This should reset the breaker. If the voltage is not present at the output terminal of the breaker after resetting it, then replace the breaker as it has a fault in it.
Turning the breaker on allows the power to flow through to the outlets, lights, and appliances on that circuit, so yes power goes to and through a turned on breaker. If the breaker is off, but the main power is on, power still get to the breaker, usually from the bus bar that runs down the middle of the back of the breaker box.
a circuit breaker trips on overload,if this breaker has tripped many times it may be worn out,if there is a overload happening the breaker is doing it s job keeping you safe.Main breaker needs to be replaced when your meter has been pulled(removed from metersocket)Have a electrician look at it and verify problem, you should not attempt to change out yourself it will be live.......
Turn the thermometer switch to offTurn the electrical service switch by the furnace to offTurn off the main breakerAfter turning off the main breaker disconnect the power line to the furnace
If a single pole switch is wired to be a master switch, the switch would have to be in the on position for any other control devices to operate. Turning the master switch off would eliminate power to all devices (and/or loads) which it was serving. For example, some homes have a switch to control their outside light. If the outside light has a photo eye (the light will only come on at night), the switch is the master switch. Another example would be the breakers in an electrical panel. Each breaker would be the "master switch" for the circuit it protects. The main breaker in the panel would be the "master switch" for the entire home.
The breaker will have a black wire connected to it. Turn off the main breaker and then disconnect that black wire from the breaker. The breaker will snap into the main bar. Remove the breaker and install the new one. Reconnect the black wire to the breaker and then install the cover and turn the main breaker back on.
No, it is still live even when the switch is open...
The wiring is like this:[[30KW Motor ---- Star Delt Starter(100A Breaker inside) ----- 200A Breaker------50A Breaker(Inside the breaker box which located inside the factory) -----100A Main Breaker]]Once I try to start the Motor, the Main Breaker trips immediately.
The amperage capacity of the main bus bars and the connection of the main breaker to the bus bars.
You can reduce the breaker size because that limits the current that can reach the main panel. There is no safety issue other than the significant danger in an unskilled person changing out a main breaker.