answersLogoWhite

0

How birefriengence be measure using babinet compensator?

Updated: 9/17/2019
User Avatar

Wiki User

15y ago

Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: How birefriengence be measure using babinet compensator?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What are the risk of using and compensator in a handgun?

Improper installation.


What is difference between lag compensator and lead compensator?

The difference between a lag compensator and lead compensator is that the lead compensator modify the transient response of the system while the lag compensator modifies the steady state.A Compensator Gc is of the form K*A(S+1/T)/(S+1/(AT))the S=-1/T is the additional zero and S= -1/(AT) is the additional pole. For a lead compensator, A is between 0 and 1 while for the lag compensator A is bigger than 1 which allows of an appreciable change in gain, hence a change in steady state response.A lead-lag compensator is a component in a control system that improves an undesirable frequency response in a feedback and control system. It is a fundamental building block in classicalcontrol theory. Contents [hide]1 Applications2 Theory3 Implementation4 Intuitive explanation5 References6 See also7 External linksApplicationsLead-lag compensators influence disciplines as varied as robotics, satellite control, automobile diagnostics, laser frequency stabilization, and many more. They are an important building block in analog control systems, and can also be used in digital control. Given the control plant, desired specifications can be achieved using compensators. I, D, PI, PD, and PID, are optimizing controllers which are used to improve system parameters (such as reducing steady state error, reducing resonant peak, improving system response by reducing rise time). All these operations can be done by compensators as well. TheoryBoth lead compensators and lag compensators introduce a pole-zero pair into the open loop transfer function. The transfer function can be written in the Laplace domain aswhere X is the input to the compensator, Y is the output, s is the complex Laplace transform variable, z is the zero frequency and p is the pole frequency. The pole and zero are both typically negative. In a lead compensator, the pole is left of the zero in the complex plane, , while in a lag compensator .A lead-lag compensator consists of a lead compensator cascaded with a lag compensator. The overall transfer function can be written asTypically , where z1 and p1 are the zero and pole of the lead compensator and z2 and p2 are the zero and pole of the lag compensator. The lead compensator provides phase lead at high frequencies. This shifts the poles to the left, which enhances the responsiveness and stability of the system. The lag compensator provides phase lag at low frequencies which reduces the steady state error.The precise locations of the poles and zeros depend on both the desired characteristics of the closed loop response and the characteristics of the system being controlled. However, the pole and zero of the lag compensator should be close together so as not to cause the poles to shift right, which could cause instability or slow convergence. Since their purpose is to affect the low frequency behaviour, they should be near the origin.


Using a ruler how to measure an angle?

You cannot measure an angle using a ruler.


How do you measure egg to g?

Using a balance able to measure 0,1 g.


What are some of ways you measure things around us?

Some ways to measure things around us include using rulers or tape measures to measure length, using scales to measure weight or mass, using thermometers to measure temperature, using clocks or watches to measure time, and using graduated cylinders or beakers to measure volume. Additionally, instruments such as spectrophotometers can be used to measure the intensity of light, and sensors such as pH meters can measure the acidity or alkalinity of substances.


How do you measure the length of a bass in Texas?

By using a tape measure


Which would you measure by using milliliters?

you measure liquid or volume.


What would you measure using a thermometer?

You would measure temp.


What could you measure using a measuring clyinder?

we can Measure volume


How do they make machines?

Adding the lense of night goggles to the compensator, thus having the linear equalities improve upon the story. With this final sequence, your baby can play Baseball as well as using an x-Ray machine.


What is the tool to measure volume using water displacement?

A beaker is used to measure volume using water displacement.


Advantages and disadvantage of using the GDP as a measure of productivity and economic health?

The advantages of using GDP as a measure of productivity and economic health is that GDP is universal and can be used to measure an economy's growth or decline. The disadvantage of using GDP as a measure of productivity and economic health is that it does not effectively measure the quality of products.