The best way to determine which circuit breaker is for the water heater is with a voltage meter, It is suppose to be only one circuit breaker, but in a faulty application it could be two breakers
The owner's manual should specify the location of the internal circuit breaker, if your particular model has one.
The breaker for the overall circuit should be in the breaker box with all the others.
10/3 wire with 30 amp double pole breaker from panel box to water heater.
Sounds like it is a 220-240 Volt hot water heater. The black and red are connected to the 220 volts supply and the white is connected to Neutral. At the breaker panel red and black connect to the 2-pole 220 volt breaker and white goes to the neutral bus bar.
In North America the standard sizes for breakers are 15, 20, 30, and 40 amps. The 15 amp size breaker is used in general circuit wiring. The 20 amp size breaker is used for dedicated appliance receptacles, hot water tank and baseboard heating. The 30 amp size breaker is used for a clothes dryer. The 40 amp size breaker is used for the electric range.
A typical home hot water heater uses 4800 watts. The circuitry connecting to the tanks is a 20 amp breaker with #12 wire for the connection. The tank draws 20 amps. W = A x V = 20 x 240 = 4800 watts. Some industrial hot water tanks can be rated at four times the size of home tanks.
What governs the type of breaker is the voltage and wattage of the heater elements. If the tank is 120V then you would only use one breaker. The size of the breaker you use will depend on the watts of the element. Watts = amps x volts, Amps = Watts/ volts. Once you establish the amperage then size the wire and the breaker to fit. If the tank is 240V the same rules apply only you would use a 2 pole breaker. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS. If you do this work yourself, always turn off the power at the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicatorto insure the circuit is, in fact, de-energized.
Because hot water heater breaker has tripped, or hot water heater has failed.
Assuming you are referring to a 240 volt residential hot water heater you will need to install 10/2 NM cable (Romex) with ground from the service panel to the water heater wired to a 30 amp circuit breaker in the service panel. If you cannot see the water heater from the service panel you will need to install a service disconnect at the water heater.
the hot water circuit beaker
If the tub is not getting hot water the issue is probably with the hot water heater. The hot water heater may have tripped a breaker or the pilot light went out.
turn off your water
Only if the hot water breaker is turned off.
yes, the breaker just controls the heating elements
YES!!
There are a number of causes as to why a hot water heater would stop heating the water. It could be due to a fault in the circuit breaker or a problem with the element, limit switch or thermostat. Unless you know what you are doing, you should contact a qualified plumber or electrician to rectify the issue.
A stove is a two pole 50, and hot water heater i would recommend the same.
The wattage of the water tank is needed to size the breaker and the wire to feed the tank.
Waking up to no hot water is not necessarily indicative of needing a new water heater. It is possible the pilot light is out, fuse is blown or circuit breaker tripped. Whosmyplumber.com is a great resource for finding a repair service.