Assuming you are referring to a 240 volt residential hot water heater you will need to install 10/2 NM cable (Romex) with ground from the service panel to the water heater wired to a 30 amp circuit breaker in the service panel. If you cannot see the water heater from the service panel you will need to install a service disconnect at the water heater.
Branch circuits are protected by the circuit breaker found in the electrical panel. Each circuit should have its one breaker. The breaker should be rated to protect the insulation of the wire, so you can determine the breaker size based on the circuit conductor size Example #14-2 should be protected by a 15 amp breaker
When installing a circuit breaker, you size the breaker based on the wire size. The breaker should be matched to the ampacity of the wire to ensure proper protection against overloads and short circuits. The device being controlled by the breaker is not a determining factor in sizing the breaker.
A 15 amp dedicated circuit breaker should be used for the dishwasher. The disposal can be wired to the general kitchen 15 amp circuit.
The pool light is usually on a 15 amp circuit. The breaker feeding this circuit must have a GFCI rating.
The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.
The size of the circuit breaker for a pool pump should be determined by the pump's current draw. The breaker should be sized to accommodate the pump's full load amperage with a 125% safety margin. Most pool pumps typically require a 15 or 20 amp circuit breaker.
For a standard refrigerator, a 15-20 amp circuit breaker is typically recommended.
For a TNIA 10 (Thermal Magnetic Circuit Breaker), the appropriate breaker size would depend on the specific requirements and rating of the circuit it is protecting. The breaker size should be chosen to match the maximum current rating of the circuit it is installed on to ensure proper protection against overcurrent. It is recommended to consult the manufacturer's specifications and guidelines for selecting the correct breaker size for the TNIA 10.
A circuit breaker protects the wires that the devices are connected to. If the devices that are connected to the circuit are 20 amps the wire size should be #12 wire fed from a 20 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. If the devices that are connected to the circuit are15 amps the wire size should be #14 wire fed from a15 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. Putting 20 amp sockets on this 15 amp circuit will work but the circuit is limited to the amount of load that can be plugged in. You will not get the full capacity of the 20 socket because the breaker will trip at 15 amps.
The size of the amp circuit breaker needed for a geyser will depend on the specific electrical requirements of the geyser. It is important to consult the geyser's manufacturer specifications to determine the appropriate amperage for the circuit breaker. Typically, a 20-amp circuit breaker is commonly used for residential geysers, but larger geysers may require a higher amperage circuit breaker. It is crucial to ensure that the circuit breaker is properly sized to prevent electrical hazards and ensure safe operation of the geyser.
The recommended range breaker size for a circuit breaker in a residential electrical panel is typically between 15 to 20 amps.
For a 240-volt circuit that requires a 50 amp breaker, the appropriate size of the breaker needed is 50 amps.