0

Yes

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

How many amps does a 600 watt low voltage transformer box pull?

The transformer itself does not pull current. Whatever you connect to the transformer pulls current. Whatever the output voltage of the transformer is, divide that into 600 and you get maximum current possible without burning up the transformer. At 24V that's 25 amps.


What are the disadvantages of a double wound transformer?

There is no disadvantage with a current transformer -it does exactly what it's supposed to do, that is:reduce the current flowing in the primary circuit to a value that can be handled by its burden (ammeter or protective relay).electrically-isolate its secondary circuit from the primary circuit.


How can you connect current transformer to ammeter in three phase?

You use three CTs, one per line conductor, each feeding a separate ammeter,


Fundamental principle of current transducer?

The basic principle of current transformer is same as that of the power transformer. Like the power transformer current transformer also contains a primary and a secondary winding. Whenever an alternating current flows through the primary winding alternating magnetic flux is produced, which then induces alternating current in the secondary winding. In case of current transformers the load impedance or "burden" is very small. Therefore the current transformer operates under short circuit conditions. Also the current in the secondary winding does not depend load impedance but depends on the current flowing in the primary winding.


What precaution should be taken when working with current transformer that is in service?

Its secondary must never be open circuited. If its burden is to be removed, then the secondary must be short circuited first, and removed only after the burden is replaced.


Can I connect current transformer in series?

CT(Current Transformer) is used to measure current flowing in the circuit. Current can be fully drawn or sensed in series condition. That's why , it is connected in series. In parallel , the current is divided; and hence the total current cannot be measured)


Why transformer cannot work on dc voltage?

In DC, flow of current is controlled by resistance only where as in AC it is done by Impedance which is combination of Resistance , inductive and capacitive reactances.Reasons:In transformers resistance of the transformer's core windings are very low due to which if you will connect transformer across DC supply then it will draw a heavy current which will burn out is winding and it may damage the equipment too.Transformers works of the principal of Induction (Mutual/Self) that is possible in AC only because in DC there is no induction therefore even if transformer's windings anyhow withstand with DC there will be no voltage output at output terminals of the transformer, therefore it is useless to connect transformer on DC supply.


How do you jump out a neutral current transformer?

To jump out a neutral current transformer, you typically connect a jumper wire across the secondary terminals of the transformer. This effectively bypasses the transformer, allowing the circuit to function without it. Ensure that the power is turned off before performing this operation for safety. Always follow safety protocols and consult the equipment's manual for specific instructions.


How is current controlled in welding transformer?

in welding machine, the transformer used is basically a current transforrmer. so by changing the tap of secondary side of transformer, we can increase or decrease the current in the transformer.


What is principle of Current transformer?

why does have to short-circuit secondary wire of current transformer ?


What is CT burden in electrical engineering?

CT (current transformer) Burden is the maximum load that the CT secondary can drive (e.g. meters or protection relays) Why do you care about burden when ordering current transformers? The burden is the termination impedance of the measuring instrument. The measuring instrument can be an analog or digital energy meter, a data logger or a recorder. All instruments that use a current transformer to measure line current must terminate the CT with a resistance (impedance in same case which means there is some inductance involved). A CT supplier should be given the burden when ordering. Technically, the total burden for a CT is the internal winding resistance, the connecting lead resistance and the measuring instrument input resistance. Some Ct's are installed a long distance from the measuring instrument and the connecting leads can have a resistance as much as 0.002 ohms per foot (both ways because the current makes a complete round trip). This resistance will cause an error if not taken into account.


Difference between potential transformer and current trasnformer?

The difference between current transformer and potential transformer is that the secondary of a current transformer can not be open circuited while under service whereas that of the potential transformer an be open circuited without any damage to the transformer.