There are many factors.
First of all, there is the temperature of the water. Next, the is the volume of water. Next there is the amount of pressure gradually built up in the boiler. Next you have the amount and speed at which heat is transferred to the water.
evaporation is liquid turn to steam .
rate is 34.5 lb multiply by hp
it is a closed system, the earth operates on a water budget in which deficits in one part are balance by gains in another part.
In a system at constant vapor pressure, a dynamic equilibrium exists between the vapor and the liquid. The system is in equilibrium because the rate of evaporation of liquid equals the rate of condensation of vapor. -KarkatHorns
air standard cycle is theoretical cycle and actual cycle is .................
It creates heat, heat boils water in closed boiler into pressurised steam, expanding pressurised steam drives steam turbine blades, steam turbine drives generator creating electricity, electricity powers metro system
If you know the temperature, pressure and volume of the vessel, you can calculate the amount of moles through the Ideal gas law. PV = nRT That is assuming you have ideal conditions. If not, a variance of the ideal gas law can be used in order to get the moles of your gas.
In boiler which is a closed vessel fluids are heated & stored for use in different processes
A boiler can be a closed system if you include the pipes it is connected to, but usually there are relief valves that will allow the escape of steam to protect against excess pressure and inlets that will allow adding liquid to the boiler to make up for fluid lost from the pressure valves. Also most boilers are imperfectly sealed so they leak a little bit. If you do not consider the attached piping, then a boiler would not be considered a closed system since it would be constantly sending out steam and receiving condensate in return.
humidity effects the evaporation in the following ways: 1. In a closed container rate of evaporation will have a lesser value than usual.but there will be no decrease in the rate.
No. The pilot valve is closed when no flame is sensed by the thermocouple.
Yes. Until the humidity reaches 100 %.
Damper is not operating according to flame (high/low) OR Diesel accumulated in Combustion chamber /Ehaust damper may be closed
euphoria
since photosynthesis does not take place at night, stomata is closed, thus, water evaporation will cease
It is a small, valve usually used to manually check if water is above the valve connection on a boiler or tank. There may be several of them at different heights on the boiler or tank. There is a handwheel on the valve, an inlet connection (which is attached to the boiler) and an outlet (usually left unconnected). When filling the boiler or tank, the try-cocks can be left open. Water coming from the try-cock means the tank is filled to at least that level. The valve is then closed.
The feed system cycles between boiler and turbine and enables the steam to return to the boiler as feed water. A closed feed cycles a main propulsion steam run turbine through a high pressure water tube boiler. The condenser, set to a high vacuum, will receive the steam turbine exhaust.
The feed system cycles between boiler and turbine and enables the steam to return to the boiler as feed water. A closed feed cycles a main propulsion steam run turbine through a high pressure water tube boiler. The condenser, set to a high vacuum, will receive the steam turbine exhaust.
When the umbrella is opened its surface is now bigger than if it was closed. If the surface is bigger, the water evaporation will occur faster.