There is not enough information stated as to what you are trying to do.
Change the outlet to a grounded one. Get an adapter that goes from 3 prong to 2. Break the ground prong off. Any one of these will work.
Only if you wanted to fry your hair.for God sake(and yours)buy a new cord to hook up your dryer
Disregard the neutral
Black & Red are hot, and White is neutral. If it has no place to connect neutral connect neutral to ground.
Do not use this type of cable to feed a 120/240V dryer outlet. The outlet is ungrounded, and the third conductor is neutral not ground. Your ground wire must be sheathed by code. You cannot use the bare neutral conductor as ground. Diagram Did Not Come Through. You Have a 3 Prong Connector. The Prong On The Bottom By Its Self Connect The Bare Wire. That Is What Was # 3 Connect The Others To The Two Prongs Next To Each Other. Hope This Makes Some Sense (1) (2) (3) Connect White To (1), Connect Black To (2) Bare (3) Good Luck
No you can not you will need to replace the plug with a 4 prong the same as the style of your oven and change your breaker to the correct Amp for your style of 4 prong plug
Plug a lamp into a working socket of an outlet to ensure the lamp works. Then turn off the switch and plug lamp into all outlet sockets, top and bottom outlets until the lamp doesn't light. Then turn on the switch and the lamp should light. Often a switch in a bedroom is only connected to one socket in a duplex outlet. It is possible to remove a jumper in an outlet to isolate the sockets for just this purpose. Often an electrician will install the outlet upside down (The third prong pointing up, to identify the outlet.
Sounds like you want to connect a three-phase machine to a single-phase supply. Very inefficiently, a three-phase motor can be ran on single phase by electrically displacing the windings with a capacitor. Other than that, you will need to either look at getting yourself a phase change converter, or having a three-phase outlet installed.
Yes, provided that you have a ground wire in the box and that the ground wire is properly connected in the electric panel.
Yes, provided the outlet has a three element receptacle. The third prong is ground. If you use an adapter that connects three prongs to a two slot outlet there is a shock danger.
Buy a tester. They are very cheap and will tell you at a glance if the outlets are wired correctly. The only other way is to remove the outlet and look see. But if it is a 2 prong outlet with no ground hole then it does not have a ground.
You don't, you need a three wire to correctly make the connection.