Best Answer

You let it totally empty with pump OFF, then with valve to service closed, you switch pump ON till water comes to level of service pipe (usually about 1/10 full. ) Now switch pump off and fill the tank with 28 psi of air. Now it is no longer waterlogged.

You let it totally empty with pump OFF, then with valve to service closed, you switch pump ON till water comes to level of service pipe (usually about 1/10 full. ) Now switch pump off and fill the tank with 28 psi of air. Now it is no longer waterlogged.

User Avatar

Wiki User

9y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

9y ago

You let it totally empty with pump OFF, then with valve to service closed, you switch pump ON till water comes to level of service pipe (usually about 1/10 full. ) Now switch pump off and fill the tank with 28 psi of air. Now it is no longer waterlogged.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you fix a waterlogged galvanized well water pressure tank?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What if you have water pressure surges when you flush the toilet?

If your water comes from a well and you have your own pump and tank. The tank may be waterlogged.


What causes low water pressure and black sediment in well water?

Something is wrong in your pressure tank, possibly waterlogged and rusting.


How to tell if a pressure tank is going bad?

If it's a galvanized tank, it would be leaking. If it's a bladder tank, it will not have any air pressure in it and there may be water coming out of the valve stem. It will also be very heavy. bob...


Why does a well pump keep cycling?

The pressure switch could be faulty, the pressure tank could be waterlogged, the pump intake could be at static water level. Call a well technician.


Why is your pressure tank kicking in 2 times in 1 hour with no water running?

It is not your pressure tank 'kicking in ' -it is the pump switching on and off. It will soon fail if this problem is not fixed. There is possibly an air leak in the system between well and tank, or the tank is ' waterlogged' - that is, full of water with no air charge. Call a well guy -NOT a plumber.


Why does the pump cycle on and off very quickly all the time any faucet is open with a none bladder water tank?

I believe that your pressure tank is "waterlogged", meaning, there is very little if any air trapped at the top of the pressure tank. A simple solution is to shut off the supply to the tank. Then completely drain the tank. And, finally, refilling the tank which will trap a sufficient amount of air, which will compress under pressure, allowing your system to have a larger operating pressure range. Good Luck.


Why do you need to have a water tank?

If water doesn't go into the pressure tank you will not have water pressure.


What would cause well water to run really slow It takes an hour and a half just to fill my washer?

There are manty things thast can cause this. Most likely is a 'waterlogged' pressure tank. That is inadequate air charge in the tank. Get a well technician to check it .


How do you fix a waterlogged pump tank?

you gotta find and remove the top tank plug - drain some water from the tank bottom to let some air get in the tank top and replace the top plug.


What happens if a bladder is broke in pressure tank is?

depending on many different situations, your bladder in your pressure tank can be broke and it can still work if your pressure tank is vertical with inlet down and your bladder just has a hole or crack in it. Most of the times however with a damaged bladder the pre pressurized air inside the tank will over time leak into the water system and then your pressure tank will not work properly. Sometimes on pressure tanks that sit vertical and have a ruptured bladder the pieces of the bladder clog the inlet/outlet thus making the pressure tank fail and it can be a pain if its a bigger pressure tank to remove because it will not drain out the water. Most pressure tanks have a air inlet on top or opposite side of the water inlet/outlet and should always be precharged of air pressure psi depending on the amount of water pressure like example 15-18 air psi if water system is running at 55-60 psi. One way to find out if your bladder is broke or precharged in your pressure tank is to drain the water pressure out then put a air gauge on the air fitting of the tank and see if it has pressure.


How do you pump up the pressure in a cold water tank?

residual air pressure in the tank, and the pressure switch settings


How do i maintain water pressure in my well?

with a pressure tank and pressure switch