there will be current that isn't carried by the current carrying conductors
Yes, a loose neutral wire can effect the operation of Earth Leakage Circuit Breaker.
Ground / earth protection will not impact cable sizing.
Earth leakage current or ground leakage current is current going where it is not supposed to be going (whether it is on a laptop or not). Power line current should only flow between hot and neutral. The earth or ground line is only there for safety purposes to keep the metal chassis at 0V at all times.
An earth leakage relay is an electronic or electromechanical device that detects the current flowing to earth (Americans call this ground). If this earth leakage current is above a preset level (and carries on for a preset time) the relay is "tripped" - this may switch on an alarm signal - or more usually it simply disconnects the supply. Currents may flow to earth due to a fault condition or because of lots of individual items connected to the supply have a small "leakage" to earth.
Seat leakage is defined as leakage that is internal to a valve-between the inlet and outlet sides of the valve-when the valve is in its closed position. It is not limited to leakage across the valve seat, but also encompasses all leakage across the valve trim when the valve is in the closed position. Leakage across internal trim seals, such as piston rings, and across trim-to-body seals, such as gaskets, can be counted as seat leakage. It is important to note that, while leakage through valve stem packing is of growing concern in the industry, governing industry standards address this type of leakage separately and do not consider it to be a form of seat leakage.
when you can't stop farting for the life of you and you occasionally have anal leakage. Note anal leakage could be a bad sign.
The best way to stop earth leakage is to make sure that the are no active circuits going to ground. This will help keep the circuit running right.
Yes, a loose neutral wire can effect the operation of Earth Leakage Circuit Breaker.
ELDB is Earth Leakage distribution board it is used for earth fault.
What is the definition of earthing and how it works?
http://www.irh.com.au/News/news_Wiring.pdf
10mA
Earth leakage relays are instantaneous tripping relays where as earth fault relays have the option of time and ampere setting i.e. for a setted ampere the circuit breaker will be tripped off after the setted time (in second).
1. If there is fluctuation in electricity and you are using manual stabilizer. 2. If there is improper earthing or earth leakage. 3. If you are using d,ble earthing.
Don't know
Ground / earth protection will not impact cable sizing.
know one cares about the earth ,read a few books, got your answer