Best Answer

on smaller stuff its usually 10ma since that is not usually fatal

default for most gfci

on larger stuff if its not connected with RMC even if you pull a ground wire be very careful

pre made cable BX (MC now) comes in large sizes ive used 2/0

the ground is #6 if there isn't a driven ground on the machine the fault could be carried in the little helix of galvanized wrapped around the cable.

now gee ill just put on an ohmmeter and make sure it wont get red hot

remember the word helix. the dc resistance doesnt change no matter what shape the wire is.

so use an LCR bridge not an ohmmeter

a caution sometimes these use 1000hz as a default

sealtite liqitite greenfeild all have this quirk

some have copper with the galvanize steel but the only thing that changes the inductance is the # of turns (well diameter too)

tray cable does not it seems to be always braided but im not positive

some hi voltage cable has the drain wires in a helix and the runs are usually longer .. on the plus side most bigger stuff has any parameter you could name settable in the breaker.

I did once learn the hard way that the suction hose on a 3" water pump is made with the same helix so it wont be pumped flat

takes about 3 amps at 277V

vom says 12 ohms perhaps its stainless wire

pumps merrily away and the hose steams a bit

perhaps the hose is a better ground than the plate at the bottom of the wood pole

plant has 480 277Y pole looked like one leg grounded delta

takes a bit of thought

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you select an earth leakage setting?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the difference between Earth Fault Relay and Earth Leakage Relay?

Earth leakage relays are instantaneous tripping relays where as earth fault relays have the option of time and ampere setting i.e. for a setted ampere the circuit breaker will be tripped off after the setted time (in second).


How do you solve earth leakage?

The best way to stop earth leakage is to make sure that the are no active circuits going to ground. This will help keep the circuit running right.


Can loose neutral wire effect the operation of Earth Leakage Circuit Breaker?

Yes, a loose neutral wire can effect the operation of Earth Leakage Circuit Breaker.


What is ELDB in electrical?

ELDB is Earth Leakage distribution board it is used for earth fault.


How does an earth leakage transformer work?

What is the definition of earthing and how it works?


What is the function of cable select jumper setting?

The function of cable select jumper setting is to let the cable select which drive takes priority ("master") and which one comes after ("slave").


How do you reset the iTunes equalizer?

If you want the iTunes equalizer's controls reset to a central position select Flat from the menu. If you have a favourite setting you wish to reset to select Make Preset from the menu and give your setting a name. You can then select your saved setting from the menu.


How do you select a setting in a dialog box?

click it


What is computer monitor earth leakage?

http://www.irh.com.au/News/news_Wiring.pdf


What is the minimum Earth fault current that an Earth leakage protection unit must be able to sense?

10mA


What causes the lubricant to leak out of the ball joints?

Leakage can happen due to low joint articulation. Select ball joint articulation of 50 degree all around. Leakage may happen in the absence of clamping for rubber boot. Select ball joint rubber boot with positive clamping arrangement.


How does cable sizing calculation gets affected by earth leakage protection?

Ground / earth protection will not impact cable sizing.