Q: How does condenser size affect the seer?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you put a 13 seer condenser on a 10 seer evaporator?

Yes you can but you will NOT get the 13 seer rating from the condenser..


Can you put a 14 seer condenser on a 10 seer evaporator?

Yes but you won`t get 14 SEER.


What is the seer rating on a model 13aja42b01 condenser?

your unit should be a 13 seer 3.5ton


16 seer coil with 13 seer condenser?

The seer doesn't matter if it will function or not it will. Just keep in mind that you will only get 13 seer max out of system


What is the seer rating for a 2 ton Goodman ck24-1b condenser?

10 SEER is the rating for the Goodman CK24-1B.


What is the SEER rating on a comfortmaker AC unit Model ACS036A2C1 1997 year unit?

That is a 9 seer condenser


Can the overall seer rating be higher than the seer rating on the condenser?

If the term "condenser" is reffering to the "condensing unit", the answer is yes. The combination of indoor coils and outdoor units is how the overall SEER is derived. The ARI website lists many combinations of these units.


What size condenser do you need to match a 5ton 10 seer coil that is at least 9 years old?

A 5 ton 10 SEER condenser will do it, but you can no longer buy a 10 SEER condenser. Replacing the condenser and not matching it with the proper evaporator coil will nullify the SEER value stated on the new unit and your actual SEER and EER will be anyone`s guess so do not pay any attention to it. The coil is the least expensive component of the 3 and now would be the time to upgrade away from R 22 which is currently being phased out and will become very expensive in the near future. Something to consider if that 9 year old coil were to fail before the new condenser does or if you were to develop a troublesome leak. But if you are dead set against the coil replacement I suppose a 4.5 or 5 ton, depending on the climate where you live will work. Get the lowest SEER currently available (13) since it will mean nothing.


What are the dimensions of a 13 seer coil?

Depends on the manufacturer and which coil (the evaporator or the condenser).


Need info on 13 seer split heat pump?

I have a4 ton air handler and a three and a half ton condenser 13 seer goodman heat pump will my seer change


What is the Goodman air conditioner model number CKL49 1L tonage?

It is a 4 ton ten seer a/c condenser


Does a condenser affect the performance of the car?

The AC condenser would effect the performance of the AC system in the car.