answersLogoWhite

0

How is ftir studies done for liquid samples?

Updated: 9/17/2019
User Avatar

Wiki User

11y ago

Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: How is ftir studies done for liquid samples?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the source of FTIR instrument?

Don't know, but go on Wikipedia, it will tell you.


Range resolution of FTIR?

I always use 400 - 4000cm-1.


Why use KBr in FTIR?

The crystal has no visible peaks in the infrared spectrum making it transparent in ftir.


Why NaCl is not used in FTIR?

It is used but not after wavelengths higher than 15 micrometres.


Where is a carbonyl group detected by FTIR?

At around 1700-1800 [1/cm]


What are the advantages of FTIR?

FTIR instruments have distinct advantages over dispersive spectrometers: 1. Better speed and sensitivity. 2. Internal laser reference. The use of a helium neon laser as the internal reference in many FTIR systems provides an automatic calibration. 3. Increased optical throughput. 4. Simpler mechanical design. 5. Elimination of stray light and emission contributions.


What is range for FTIR?

FTIR or Fourier transform Infared spectroscopy is the simultaneous collection of spectral data in the wide spectral range.Which has quite an advantage over a dispersive spectrometer which only covers a narrow range of wave lengths at once.


Types of soil test?

macro and micro mutrients test in soil through FTIR


Thermo fisher scientific model ftir nicolet 6700?

this is an equipment used to perform DRIFT analyses


What is the principle of FTIR?

The principle of FTIR is based on the fact that bonds and groups of bonds vibrate at characteristic frequencies. A molecule that is exposed to infrared rays absorbs infrared energy at frequencies which are characteristic to that molecule. In a molecule, the differences of charges in the electric fields of its atoms produce the dipole moment of the molecule. Molecules with a dipole moment allow infrared photons to interact with the molecule causing excitation to higher vibrational states. Diatomic molecules do not have a dipole moment since the electric fields of their atoms are equal. During FTIR analysis, a spot on the specimen is subjected to a modulated IR beam. The specimen's transmittance and reflectance of the infrared rays at different frequencies is translated into an IR absorption plot consisting of reverse peaks. The resulting FTIR spectral pattern is then analyzed and matched with known signatures of identified materials in the FTIR library.


What is ATR?

ATR = Attenuated Total Reflectance. A surface sampling technique similar to FTIR. Samples are examined directly, without preparation. Infrared radiation internally reflects through a crystal (ZeSe Diamond) penetrating the sample by only a few microns. The absorbing / scattering of the light is collected and measured to produce a spectrum which is characteristic for the compound being analyzed.


How FT-IR spectrometer is used for material analysis?

FTIR is an effective analytical tool for identification of unknowns, sample screening and profiling samples. The FTIR measuring principle is a measurement with IR light. Contrary to NDIR with a narrow wave length area by means of an optical filter, the scan area of the IR wave length by use of the FTIR measuring principle is large. The principle of FTIR is that the gas/solid/liquid to be analysed is led through a cuvette with an IR light source at one end that is sending out scattered IR light, and a modulator that "cuts" the infra red light into different wave lengths. At the other end of the cuvette a detector is measuring the amount of IR light to pass through the cuvette. Like the NDIR measuring principle it is the absorption of light at different wave lengths that is an expression of the concentration of gasses to be analysed. By data processing, Fourier Transformation mathematics is used to turn the measured absorption values into gas concentrations for the analysed gasses. As the light, when using the FTIR measuring principle, is modulated into many different wave lengths, it is possible to analyse many different gasses in the same instrument; such as CO, H2O, SO2, NO, NO2, HCl, HF, NH3. Using the above measuring principle also produces a much larger data material (as compared to the conventional NDIR principle), from where the concentrations of the different gasses can be measured. The large data material supply excellent calibration curves and correlation values, thus providing very reliable analysis-results. Because chemical bonds absorb infrared energy at specific frequencies (or wavelengths), the basic structure of compounds can be determined by the spectral locations of their IR absorptions. The plot of a compound's IR transmission vs. frequency is its "fingerprint", which when compared to reference spectra identifies the material. FTIR spectrometers offer speed and sensitivity impossible to achieve with earlier wavelength-dispersive instruments. This capability allows rapid analysis of micro-samples down to the nanogram level in some cases, making the FTIR unmatched as a problem-solving tool in organic analysis. The FTIR microscope accessory allows spectra from a few nanograms of material to be obtained quickly, with little sample preparation, resulting in more data at lower cost. In some cases, thin films of residue are identified with a sensitivity that rivals or even exceeds electron or ion beam-based surface analysis techniques. FTIR relies on the fact that the most molecules absorb light in the infra-red region of the electromagnetic spectrum; this absorption corresponds specifically to the bonds present in the molecule. The sample is irradiated by a broad spectrum of infra-red light and the level of absorbance at a particular frequency is plotted after Fourier transforming the data. The resulting spectrum is characteristic of the organic molecules present in the sample. It has 600 - 4000 wavelengths. Used for the identification and quantification of organic species. Is capable of ultra trace organic analysis, e.g. for contamination on surfaces In addition to "standard" transmission FTIR we they also have the following sample handling capabilities: # Horizontal ATR - attenuated total reflectance. Allows measurement of aqueous solutions, elastic and viscous samples which are difficult to grind # Specular reflectance - allows measurement of thin films on metals # KBr Discs - allow suspension of powders in IR transparent KBr so they may be analysed # Gas cells - This may be used for FTIR analysis of a gaseous sample (e.g. headspace analysis or environmental monitoring) # Solution cells - for measuring liquid sample in transmission mode.