According to the NEC, if the ground rod supplements another grounding electrode such as a metal water pipe, you are required 1. If the ground rod or rods is your only grounding electrode, you are required at least 2, at least 6 feet apart. Check with your local jurisdiction for local requirements.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

What size ground wire is needed for 200amp service pannel in Chicago?

200 amp service in chicago uses 3 aught.


What size ground wire needed for a 200amp service panel in new jersey?

#6 bare copper wire.


What size grounding wire do you use as the 4th wire running in your conduit from your 200 amp meter box to your 200amp service panel this is the ground wire from box to box?

For a 200 amp service, you would typically use a 4/0 AWG copper wire for the grounding wire running between the meter box and the service panel. This size is suitable for carrying the necessary current and providing proper grounding protection for the electrical system.


How do you bond a 200amp service panel?

To bond a 200amp service panel, you need to connect the grounding bar and the neutral bar in the panel using a bonding strap or screw provided by the manufacturer. This establishes a direct connection between the neutral and ground conductors, ensuring proper grounding and safety for the electrical system. It's important to follow the manufacturer's instructions and local electrical codes when bonding a service panel.


What size wire to ground water pipe?

The wire used to ground a water pipe typically needs to be a minimum of 10 AWG copper wire. It's always best to consult with local building codes or a licensed electrician to ensure that the proper size wire is used for grounding.


Where can one find an above ground pool deck installation company in Indianapolis?

I just put in a new above ground pool. Is there someone in Indianapolis that can install a deck?


Did dhl sell ground service?

Yes, DHL does in fact sell ground service. However, it is not called ground service. Rather, it is called domestic service.


Is a ground wire required on a church fiberglass steeple?

no


How Much area is required for a Tennis Ground?

How much area is required for a Basket Ball Court


What is the required distance between ground rods for effective grounding?

The required distance between ground rods for effective grounding is typically 6 to 8 feet apart.


passenger service providers?

ground aircraft handle


What size ground rod for 1200amps service?

For a 1200 amp service, the National Electrical Code (NEC) typically requires a grounding electrode system that includes a ground rod of at least 5/8-inch in diameter and a minimum of 8 feet in length. If using a copper rod, it should be at least 5/8-inch in diameter. Additionally, multiple ground rods may be required if the resistance to ground exceeds certain limits, so it's important to consult local codes and a qualified electrician for specific requirements.