Q: How voltage is reduced on a star connection?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

The Most suitable and economically connection for small high voltage transformer is?

delta star


What connection that increases voltage?

by using Y-Y(Star) transformer..... bcoz in star VL = root 3* Vph


Why is star connection used in a three phase transformer?

The power of all three phases can be transmitted on three conductors.A star connection, as opposed to a delta, provides a grounding reference. Also, for ground faults on the secondary (assuming no delta third winding, or source third winding) will be a direct ratio similar to phase faults, instead of 57%. Another reason is to avoid the inherent phase shift involved in a delta/star configured transformer.Another AnswerA 'star-connected' secondary is the standard European connection for a three-phase distribution transformer, as it provides a line voltage of 400 V together with a phase voltage (i.e. line to neutral) of 230 V.


Which conditions refers to a reduced voltage levels of AC power that lasts for a period of time?

Reduced voltage levels of AC power that lasts for a period of time is known as a brownout.


Why do we use star to star connection in motor?

In a high voltage installation, with the same power, current drawn is small compared to those in low voltage. However it requires a thicker insulation, thus cost of insulation is significant compared to the conductor cost. By using a star connected winding, the insulation voltage required is equal to line to neutral connection, otherwise if it is connected in delta the insulation rating has to be provided for a line to line connection. Despite having a higher current, the total cost is still lower compared to using a higher insulation rating.

Related questions

Why does an electromagnetic brake designed for a star connection not work in delta?

Probably the reason is in the different voltages between the star and delta connection voltages. An electromagnetic brake designed for the lower voltage of the star connection would burn out or open when introduced to the higher voltage of the delta connection.


Power a 415volt motor with 480volts?

in low voltage connection in wye (star conncetion) 415v high voltage connection in delta 480v


The Most suitable and economically connection for small high voltage transformer is?

delta star


What connection that increases voltage?

by using Y-Y(Star) transformer..... bcoz in star VL = root 3* Vph


How is the neutral point in a star connection created?

In a distribution transformer's star-connected secondary, the common point of connection is called the 'star point' and is connected to earth. The star point then provides the neutral connection for the transformer secondary, providing a return path for any unbalanced currents due to an unbalanced three-phase load.This arrangement provides a four-wire distribution system, comprising three line conductors and one neutral conductor (in addition, there are various methods of providing an earth connection to consumers). The line-to-line voltage is called a line voltage (in the UK, 400 V), while a line-to-neutral voltage is called a phase voltage (in the UK, 230 V). The line voltage being 1.732 x phase voltage.


Why in a star connection phase voltage is 1.73times of line voltage?

It isn't. It's the other way around. The line voltage is 1.732 times the phase voltage. The figure results when you vectorially add the relevant phase voltages.


Why is star connection used in a three phase transformer?

The power of all three phases can be transmitted on three conductors.A star connection, as opposed to a delta, provides a grounding reference. Also, for ground faults on the secondary (assuming no delta third winding, or source third winding) will be a direct ratio similar to phase faults, instead of 57%. Another reason is to avoid the inherent phase shift involved in a delta/star configured transformer.Another AnswerA 'star-connected' secondary is the standard European connection for a three-phase distribution transformer, as it provides a line voltage of 400 V together with a phase voltage (i.e. line to neutral) of 230 V.


What is a timer in a star delta starter?

A timer in star delta starter for a three phase motor is an electronic device designed to do the change over or transition from star connection - using which the motor suns on a reduced voltage and current and produces less torque - to the delta connection necessary for running the motor at its full power, using high voltage and current to produce a high torque. The timing interval that is set is dependent how long the motor needs to start up from standstill to normal speed. Some motors require 15 seconds for the initial startup in star connection and after that given value of time the timer signals to the star contactor to go to the open position and the main delta contactor to go to the closed position, thus forming the delta circuit.


What is the star delta working principle?

when starting a 3 phase induction motor,first start with star connection,because reduced current is being applied and after start change it to delta connection then. full line current is applied to the motor.


When voltage is reduced 75 percent current is reduced?

This statement is correct.


Why motor connect in star connection?

hot motor are connected in star because it deals with the voltage in case small Power system, which the voltz could either drop or rise.


What is the connection of normal wire star or delta?

normally delta connection wired in 3 phase induction motor. during starting wiring is in Star and after running normal speed changeover to delta .beacause starting time its phase voltage equals less root3 times of line voltage ,line current and phase current equals. in Delta phase voltage and line voltage equals, and phase current equals root3 times line current