answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: If a split-phase motor has two poles on the main winding how many poles are needed for the auxiliary winding?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is difference between main winding and auxiliary winding?

In the case of a capacitor-start/run single-phase induction motor, the main field is provided by the main (running) winding, and the capacitive branch is the auxiliary winding. In the case of a capacitor-start motor, the main winding is the running winding and the auxiliary winding is the starting winding.


If the running winding and the auxiliary winding were connected in series would the motor run?

no


What is the number of turn in single phase motor?

If you really do mean the number of 'turns', then you cannot really determine this, as it is determined as a part of its design process and can vary considerably from machine to machine.If, on the other hand, you actually mean 'windings' ('coils') then, typically, there are two: the 'main winding' and the 'auxiliary winding'. The purpose of the auxiliary winding is to supply a magnetic field that is out of phase with the main winding and which then results in a rotating magnetic field necessary to start the motor and turn in in the desired direction.


What is the use of centrifugal switch in single phase induction motors do all single phase motors gave them?

To stop a three-phase motor dead ('plugging'), rather than allowing it to slow to a stop, the motor controller interchanges two of the three lines -which applies a reverse torque to the machine. But before the motor then gets a chance to reverse direction, the centrifugal switch trips the starter and removes the supply. <<>> The centrifugal switch that you refer to and can see in an open frame motor, is used to open the start winding of small HP single phase motors. Once the motor gets up to a certain RPM, the switch opens and the motor continues to operate on its run winding. When the motor stops, the switch goes back to its normally closed position in the start winding and awaits the next start operation.


What kind of AC load uses the energy needed to magnetize a motor or a transformer winding?

inductive load

Related questions

What is difference between main winding and auxiliary winding?

In the case of a capacitor-start/run single-phase induction motor, the main field is provided by the main (running) winding, and the capacitive branch is the auxiliary winding. In the case of a capacitor-start motor, the main winding is the running winding and the auxiliary winding is the starting winding.


If the running winding and the auxiliary winding were connected in series would the motor run?

no


Why must the auxiliary winding be different from the main winding in a split phase motor?

To differentiate it from the main winding and to make the path of the current different.


What does a capacitor on fan motors or blowers?

It is called a 'starter capacitor" and is used to provide a phase shift on the starter winding to get the motor turning in the right direction when first turned on. Once the motor is running a switch opens the starter circuit through the capacitor and starting winding, as this is no longer needed for the main motor windings to keep the motor turning.


What is the number of turn in single phase motor?

If you really do mean the number of 'turns', then you cannot really determine this, as it is determined as a part of its design process and can vary considerably from machine to machine.If, on the other hand, you actually mean 'windings' ('coils') then, typically, there are two: the 'main winding' and the 'auxiliary winding'. The purpose of the auxiliary winding is to supply a magnetic field that is out of phase with the main winding and which then results in a rotating magnetic field necessary to start the motor and turn in in the desired direction.


What is the use of centrifugal switch in single phase induction motors do all single phase motors gave them?

To stop a three-phase motor dead ('plugging'), rather than allowing it to slow to a stop, the motor controller interchanges two of the three lines -which applies a reverse torque to the machine. But before the motor then gets a chance to reverse direction, the centrifugal switch trips the starter and removes the supply. <<>> The centrifugal switch that you refer to and can see in an open frame motor, is used to open the start winding of small HP single phase motors. Once the motor gets up to a certain RPM, the switch opens and the motor continues to operate on its run winding. When the motor stops, the switch goes back to its normally closed position in the start winding and awaits the next start operation.


How the capacitor create a phase difference in single phase induction motor?

The stator consists of the main winding and a starting winding (auxiliary). The starting winding is connected in parallel with the main winding and is placed physically at right angles to it. A 90-degree electrical phase difference between the two windings is obtained by connecting the auxiliary winding in series with a capacitor and starting switch. When the motor is first energized, the starting switch is closed. This places the capacitor in series with the auxiliary winding. The capacitor is of such value that the auxiliary circuit is effectively a resistive-capacitive circuit (referred to as capacitive reactance and expressed as XC). In this circuit the current leads the line voltage by about 45° (because XC about equals R). The main winding has enough resistance-inductance (referred to as inductive reactance and expressed as XL) to cause the current to lag the line voltage by about 45° (because XL about equals R). The currents in each winding are therefore 90° out of phase - so are the magnetic fields that are generated. The effect is that the two windings act like a two-phase stator and produce the rotating field required to start the motor. When nearly full speed is obtained, a centrifugal device (the starting switch) cuts out the starting winding. The motor then runs as a plain single-phase induction motor. Since the auxiliary winding is only a light winding, the motor does not develop sufficient torque to start heavy loads. Split-phase motors, therefore, come only in small sizes. Type your answer here...


How is the resistance of a motor winding expressed?

The resistance of a motor winding is expressed in


What kind of AC load uses the energy needed to magnetize a motor or a transformer winding?

inductive load


How capacitor help to start the motor of ceiling fan?

Most ceiling fans use a type of motor known as a "permanent split capacitor motor". These motors have two coils, a "start" and a "run" winding. A capacitor is connected in series with the start winding to insert a phase shift, but once the motor is up to speed it becomes an auxiliary winding. In order to reverse the motor, the capacitor is applied to the "run" winding which then becomes the "start" winding. In some cases the windings may have taps to provide different speeds, in others the value of the start/run capacitor is lowered to provide lower speeds. Yet other designs will have additional capacitors wired in series with the motor as a whole to regulate speeds.


What are the uses of damper winding s in synchronous motor?

to achive constant speed and provide a eassy way to inter loacking with syn fluxDamper winding is a short circuited winding which are useful in preventing the hunting(momentary) speed fluctuation in alternator and are needed in synchronous motor to provide starting torque.


The function of a start winding in a split-phase motor is to?

a start winding on a motor is used to add torque to start a motor, and more importantly to establish the direction that the motor will turn. to reverse a motor normally means to reverse the start winding. the run winding will work the same in either direction, the start winding determines the direction.