answersLogoWhite

0


Best Answer

According to information on the Chicago Hardware web site: "Working load limits for eye bolts are based on straight vertical lift in a gradually increasing manner. Angular load lifts will significantly lower working load limits and should be avoided whenever possible. If an angular lift is required, a properly seated Shoulder Pattern eye bolt must be used. Loads should always be applied to the eye bolts in the plane of the eye, not at an angle to this plane. Angular lifts must never be more than a 45 degree pull." The lift capacity of a shoulder eye bolt is shown to be reduced by 75% when used at a 45 degree angle. Example: 3/4-10 shoulder eye bolt @ straight pull = 6000lbs. At a 45 degree pull the same eye bolt is shown at 1500lbs. Refer to: http://www.chicagohardware.com

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: If an eye bolt is used horizontally the capacity is reduced by what pecentage of the eye bolts strength?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What would happen to a cell if the number of ribosomes was reduced?

Its capability and capacity to manufacture proteins would be reduced.


What levels used on a SITREP report is defined as reduced strength 59 percent or less fit for duty?

Red indicates reduced strength 59% or less fit for duty.


How did Khrushchev improved living conditions for the Russian people?

He reduced the strength of the secret police


Can you make a 6.2 liter a 427cubic inch?

Only if the capacity is reduced.


What status levels on a SITREP report is defined reduced strength?

pink


What status levels on a SITREP report is defined as reduced strength?

pink


What are the strength of the database?

Reduced data redundancy, Improved data integrity, Shared data, Easier access, Reduced development time


Status levels used on a SITREP reports is defined as reduced strength?

pink


What is turndown capacity?

Its is process term which means the reduced capacity w.r.t. the rated capacity. For example if plant rated capacity is x and turndown capacity is 85% that means 0.85x. And similarly the turndown ratio would be x/0.85x.


Can you get incapacity benefit and reduced earnings allowance together?

No. you have no capacity to perform. Reduced earning allowance was inplaced if you were able to perform. your out of luck. STATED BY AUTHOR


Which of the following status levels on a SIT REP report is defined as reduced strength?

red


Which level used on a sitrep report is defined as reduced strength 60 percent -79 percent fit for duty the unit is mission capable?

The color red is used to indicate the level on a SITREP report that defines an area that has been reduced in strength. Green and amber indicate levels that are performing at or above expected strength.