Updated: 4/8/2023

The ASTM F2413-05 is the consensus standard that is accepted from OSHA for protective foot wear at the workplace. The ASTM F2413-05 replaced the ANSI z41.1 standard.

User Avatar

Joshua Orn

Lvl 10
2y ago

What else can I help you with?

Related Questions

Is ASTM F2413-05 the same as ANSI?

The ASTM F2413-05 is the consensus standard that is accepted from OSHA for protective foot wear at the workplace. The ASTM F2413-05 replaced the ANSI z41.1 standard.


What is ASTM F2413?

ANSI Z41 - that was the standard for protective footwear has been replace by ASTM (American Society for Testing & Materials) F2412-05 (Testing methods for Protective Footwear) and F2413-05 (Minimum requirements for Protective Footwear). The latest addition/modification is ASTM F2413-11. The details of which can be purchased from ASTM website for USD 40- USD 48 with redline.


What is the difference in astm f2413-05 and astm f2413-11?

F2413-05, the 05 stands for 2005. It was updated in 2011 so it is now Fs413-11


What is astm f2413-11?

ANSI Z41 - that was the standard for protective footwear has been replace by ASTM (American Society for Testing & Materials) F2412-05 (Testing methods for Protective Footwear) and F2413-05 (Minimum requirements for Protective Footwear). The latest addition/modification is ASTM F2413-11. The details of which can be purchased from ASTM website for USD 40- USD 48 with redline.


Is astm f2413-11 better than astm f2413-05?

ASTM F2413-11 is an updated version of ASTM F2413-05, incorporating advancements in safety and performance standards for protective footwear. The 2011 version includes improved test methods and criteria for impact and compression resistance, among other enhancements. Therefore, ASTM F2413-11 is generally considered better as it reflects the latest industry practices and safety requirements.


What is the difference between ANSI steel toe and ASTM steel toes?

As of March 2005, ASTM F2413 standard superseded the ANSI Z41 standard. Manufacturers and distributors will implement a "running change" to their inventory from the ANSI Z41 labeled footwear. Because there is no change in the protocol, the ASTM F2413 standard does not require that the change from ANSI to ASTM labeled footwear occur in a specific time period.The protective footwear you choose must comply with the American Society for Testing and Materials (ASTM) standard F2413-05, formerly the American National Standards Institute's (ANSI) standard Z41-1999. The F2413-05 standard separates safety footwear into different categories such as Impact and Compression Resistance.ASTM F2413-05 - The letters F2413 reference the performance requirement for foot protection. The additional digits following the standard designation indicate the year of the standard to which the protective footwear complies, for example: 05 refers to 2005.M = Footwear designed for a male.F = Footwear designed for a female.I/75 = Impact rating of 75 (foot pounds)C/75 = Compression rating of 75 (2500 lbs. of pressure)The ASTM F2413 standard has two classifications for compression ratings 75 = 2,500 lbs and 50 = 1,750 lbs. This means the footwear has been tested to withstand compressive loads up to the designated number of pounds before the toe-cap will start to crush or crack.


WHAT IS DIfference between ANSI and ASTM F 2413-11?

ANSI is the American National Standards Institute. They coordinate the development of US Voluntary National Standards in private and public sectors with regards to information management and data communications. ASTM is the American Society for Testing and Materials. They develope, publish standards, definition of materials, methods for testing materials, installation practices and specifications for materials. Ok since ASTM develops the standards how does that affect OHSA standards to ANSI on safety ie.. Z87 stamp on safety glasses?


Is ASTM F2413-05 approved by OSHA?

OSHA does not approve standards, although it may incorporate some by reference.


Does bates enforcer work boots meet the ASTM F2413-05 requirement?

Yes, Bates Enforcer work boots typically meet the ASTM F2413-05 requirements, which specify standards for protective footwear. These boots are designed for safety and protection, often featuring elements such as electrical hazard resistance and steel toe reinforcement. However, it's essential to check the specific model's details to confirm compliance, as not all styles may meet the same standards.


What does astm f2413 05 175c75 mean?

f2413-05 has something to do with chain saw protection. and I think 175/c75 is some kind of osha requirement for safety footwear? F2413 is the ASTM designation for footwear protection standards for work boots. The "-05" signifies the 2005 version which was updated in 2011 and is signified with "-11" suffix. The last part "I75" (not 175) and "C75" designate (I)mpact resistance of 75 ft lbs and (C)ompression resistance of 75 ft lbs (there are boots that only resist 50 ft lbs also that would bear the designation I50 C50). There are further designations for various other properties. . .EH = Electrical isolation to help prevent electrocution. .CD - Conductive (i.e., it allows electrical grounding) for use in potentially explosive environments (where gases, explosives and volatile chemicals are present). .SD = Static Dissipative (kind of a combination of EH & CD). .PR = Puncture Resistant. .CS - Chain Saw resistant. .DI = Dielectric (a higher grade EH, I believe).


What is the difference between Dielectric footwear and Electrical hazard footwear?

Dielectric footwear meets ASTM F1117-03 (2008). This footwear is tested to 20,000v while wet. Electrical Hazard (EH) footwear meets ASTM F2413-05 or CAN/CSA-Z195-M92 Section 4.3 and is tested on the soles ONLY. EH is usually used for Low Voltages and in dry conditions. Dielectric can be used for higher voltages and in wet conditions. Usually near possible downed powerlines. These are always "secondary protection since they are not retested like D120 rubber insulating gloves. Dielectric tests in F1117 are performed on EACH shoe. F2413 is performed on a representative number and is a dry test. CAN/CSA-Z195-M92 Section 4.3 is a wet test.


What is astm f 2413-05?

Protective Footwear RequirementsDocument Number: 252Referenced in the Code of Federal Regulations (CFR) Title 29 are the Occupational Safety and Health Administration's (OSHA's) guidelines for Occupational Foot Protection (1910.136). This regulation refers to the American National Standards Institute (ANSI) American National Standard for Personal Protection - Protective Footwear (ANSI Z41) for its performance criteria. On March 1, 2005, ANSI Z41 was withdrawn and replaced by two new American Society of Testing Material (ASTM) International Standards. The new ASTM standards are F2412-05 Standard Test Methods for Foot Protection and F2413-05 Standard Specification for Performance Requirements for Foot Protection. This document provides an overview of the OSHA standard, the ANSI performance criteria and the ASTM performance requirements. Occupational Foot Protection According to 1910.136(a), "Each affected employee shall wear protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet are exposed to electrical hazards." Appendix B to subpart I identifies the following occupations for which foot protection should be routinely considered: shipping and receiving clerks, stock clerks, carpenters, electricians, machinists, mechanics and repairers, plumbers, assemblers, drywall installers and lathers, packers, wrappers, craters, punch and stamping press operators, sawyers, welders, laborers, freight handlers, gardeners and grounds keepers, timber cutting and logging workers, stock handlers and warehouse laborers. ASTM F2413-05 Requirements The ASTM F2413-05 standard covers minimum requirements for the design, performance, testing and classification of protective footwear. Footwear certified as meeting ASTM F2413-05 must first meet the requirements of Section 5.1 "Impact Resistant Footwear" and Section 5.2 "Compression Resistant Footwear". Then the requirements of additional sections such as metatarsal protection, conductive protection, electric shock protection, static dissipative protection and protection against punctures can be met. Protective footwear can meet all the requirements of the ASTM standard or specific elements of it, as long as it first meets the requirements for impact and compression resistance. All footwear manufactured to the ASTM specification must be marked with the specific portion of the standard with which it complies. One shoe of each pair must be clearly and legibly marked (stitched in, stamped on, pressure sensitive label, etc.) on either the surface of the tongue, gusset, shaft or quarter lining. The following is an example of an ASTM marking that may be found on protective footwear:ASTM F2413-05M I/75/C/75/Mt75PRCS Line #1: ASTM F2413-05: This line identifies the ASTM standard - it indicates that the protective footwear meets the performance requirements of ASTM F2413 issued in 2005. Line #2: M I/75 C/75 Mt75: This line identifies the gender [M (Male) or F (Female)] of the user. It also identifies the existence of impact resistance (I), the impact resistance rating (75 or 50 foot-pounds), compression resistance (C) and the compression resistance rating (75 or 50 which correlates to 2500 pounds. and 1750 pounds of compression respectively). The metatarsal designation (Mt) and rating (75 or 50 foot-pounds) is also identified. Lines 3 & 4: PR CS Lines 3 and 4 are used to identify footwear made to offer protection from other specific types of hazards referenced in the standard. They are used to designate conductive (Cd) properties, electrical insulation properties (EH), footwear designed to reduce the accumulation of excess static electricity (SD), puncture resistance (PR), chain saw cut resistance (CS) and dielectric insulation (DI), if applicable. Line 4 is only used when more than three sections of the ASTM standard apply. Conductive (Cd) footwear is intended to provide protection for the wearer against hazards that may result from static electricity buildup and to reduce the possibility of ignition of explosives or volatile chemicals. The footwear must facilitate electrical conductivity and the transfer of static electricity build up from the body to the ground. The electrical resistance must range between zero and 500,000 ohms. Electrical shock resistant (EH) footwear is manufactured with non-conductive electrical shock resistant soles and heals. The outsole is intended to provide a secondary source of electric shock resistance protection to the wearer against the hazards from an incidental contact with live electrical circuits, electrically energized conductors, parts or apparatus. It must be capable of withstanding the application of 14,000 volts at 60 hertz for one minute with no current flow or leakage current in excess of 3.0 milliamperes, under dry conditions. Static dissipative (SD) footwear is designed to provide protection against hazards that may exist due to excessively low footwear resistance, as well as maintain a sufficiently high level of resistance to reduce the possibility of electric shock. The footwear must have a lower limit of electrical resistance of 106 ohms and an upper limit of 108 ohms. Puncture resistant (PR) footwear is designed so that a puncture resistant plate is positioned between the insole and outsole. It is an integral and permanent part of the footwear. Devices constructed of metal must pass the ASTM B117 Practice for Operating Salt Spray (Fog Apparatus) corrosion resistance testing. The device must show no sign of corrosion after being exposed to a five percent salt solution for 24-hours. The puncture resistant footwear must show no signs of cracking after being subjected to 1.5 million flexes and have a minimum puncture resistance of 270 pounds. *Click here for puncture resistant Protecta Pac Boots #24258. Chain saw cut resistant (CS) footwear is designed to provide protection to the wearer's feet when operating a chain saw. It is intended to protect the foot area between the toe and lower leg. This footwear must meet the ASTM F1818 Specification for Foot Protection for Chainsaw Users standard. Dielectric insulation (DI) footwear is designed to provide additional insulation if accidental contact is made with energized electrical conductors, apparatus or circuits. It must meet the minimum insulation performance requirements of ASTM F1117 (Specification for Dielectric Footwear) and be tested in accordance with ASTM F1116 (Test Method for Determining Dielectric Strength of Dielectric Footwear). *Click here for SERVUS® Dielectric Boots and Overshoes #83388, #83389, and #83390.