answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: Is it possible Less voltage of one phase can start 3 phase motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Will 3 phase AC motor stay running if you remove 1 phase?

Yes but it will not start. Usually if you lose one phase the current will go higher on the other phases and the motor overload protection will disconnect the motor from the supply voltage.


How much voltage does star-Delta starter give to motor at start?

A delta starter supplies what ever the supplied voltage to the line side of the contactor is. The inrush current is usually 300% of the full load amperage of the motor. Edit to above answer: Actually the question is for a Wye-Delta Starter (Wye=Star). There are two contactors, one in Wye configuration and one with Delta. The Wye is used to start and the Delta for run. This is a reduced voltage start scheme. Though the line supply voltage remains the same, for instance 480VAC, the phase voltage at the motor will be different for the Wye: V(phase) = V(line)/1.732 In a Delta V(phase) = V(line) So the Phase Voltage during the start will be 277VAC and then when the motor is spinning, usually after a set time delay, the Wye contactor drops out and the Delta contactor kicks in so that Phase Voltage is now the full 480VAC.


How do you start a three phase motor to a single phase power supply?

You don't. A three phase motor will not start unless it is connected to a three phase supply.


Can a 3 phase slip ring motor start when its one resistance or phase is open?

A three phase motor will not start if one phase leg is open.


How do you start single phase induction motor?

capacitive start motors start by themselves however a normal single phase induction motor requires a starter motor to 'kick-start' the motor into action.


Why are no starting components needed on three-phase motors?

Yes, by using a DOL Starter, which gives a controlled "soft-start" for the motor even though it is always connected in delta configuration.In this type of starting a 3-phase motor, full voltage is applied to the motor through relays and contactors. Its is the most common type of 3-phase motor starter used.DOL means Direct On-Line starter.


Can you connect three phase AC voltage directly to motor?

I assume your question relates to the need for a disconnect switch. To meet code you need a disconnect switch in the proximity of the motor so that should the need arise the motor can be disconnected for safe maintenance or in an emergency. The motor will work directly connected, but you will create a safety issue.


How do you wire a three phase motor with capacitor start?

I have never come across a three phase capacitor start motor. Any three phase motors I have worked on are induction start.


Drawing block diagram of single phase capacitor start motor?

Drawing block diagram of single phase capasitor start motor?


What is the difference in wiring a 12 3 phase motor at low voltage between run and start?

You have to wire both the run and start windings. The start windings will automatically be removed from the circuit once the motor is at 75% of normal speed. The start winding gives you more torque to start the motor.


How can you reverse the direction of rotation in an induction motor?

A single phase induction motor has two sets of coils and a centrifugal start switch. The start winding is in series with the start switch. The start winding provides a rotating magnetic field in one direction enabling the motor to start. The motor can be reversed by reversing the connections of either the start winding or the run winding but not both.


Is three phase induction motor continue running when any of the two phase is disconnected?

This question doesn't really make any sense - any of the two phase? A three phase induction motor requires 3 phases to start - if a single phase is lost while the motor is already running then yes the motor will continue to run. A three phase motor will not start if it is missing a phase.