answersLogoWhite

0

No because it can actually crack the slide.

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

Which part of a microscope should be used with the low power objective but not with the high power objective?

The coarse focus knob should be used with the low power objective but not with the high power objective. The point of using the coarse focus knob is to bring the specimen into general focus before fine-tuning with the high power objective, which requires more precise adjustments.


Which focusing knob do you never use under high power?

The coarse adjustment knob should never be used when viewing in high power with a compound microscope. When in high power, use the coarse adjustment (the knob smaller than the coarse adj.) to more accurately focus on the subject.


What part of the microscope should you used to focus the image when using high power objective lens?

First of all, one should never call it high power, it is morecommonly called the "high objective", yet that is not what this question is asking. To answer the question: You use the fine adjustment knob. This knob should be located near the coarse adjustment knob, on the opposite side of the microscope (at the same height as the coarse adjustment knob), or even as a separate knob protruding from the coarse adjustment knob. The fine adjustment knob is smaller in size. You should never, ever use the coarse adjustment knob under the high objective, you could scratch the microscope slide, cover slip, high objective lens, or in a worst case scenario break the high objective lens.


Why should you never use the coarse adjustment knob on high power for a microscope?

Using the coarse adjustment knob on high power can potentially damage the microscope or the slide being observed due to the high magnification and close proximity of the objective lens to the slide. It is better to make coarse adjustments on low power to avoid hitting the objective lens against the slide.


The coarse adjustment knob on a microscope should never be used with the?

The coarse adjustment knob on a microscope should never be used with the high-power objective lens. This can cause damage to both the lens and the slide being viewed. Instead, it is best used with the low-power or scanning objective lens for initial focusing.


What part of the microscope should be turned to obtain a clear image under high power?

I believe it's the coarse adjustment.


6 How does the procedure for using the microscope differ under high power?

For low power you can use the coarse adjustment and fine adjustment for high power you should only use the fine adjustment because on high power, the objective lens is too close to the slide and using the coarse adjustment may scratch the objective lens.


How does the procedure for using the microscope differ under high power as opposed to low power?

use the fine adjustment knob to get a better view of what you are looking at.For low power you can use the coarse adjustment and fine adjustmentfor high power you should only use the fine adjustment because on high power, the objective lens is too close to the slide and using the coarse adjustment may scratch the objective lens.


How does the procedure for using the microscope different under high power as oppose to low power?

use the fine adjustment knob to get a better view of what you are looking at.For low power you can use the coarse adjustment and fine adjustmentfor high power you should only use the fine adjustment because on high power, the objective lens is too close to the slide and using the coarse adjustment may scratch the objective lens.


When using any high power objective you should not adjust the?

When using any high power objective, you should not adjust the coarse focus knob. This is because the high power objective lens is positioned very close to the slide, and adjusting the coarse focus can lead to crashing the lens into the slide, potentially damaging both the lens and the specimen. Instead, use the fine focus knob for precise adjustments to bring the specimen into sharp focus.


Why should you never us the coarse adjustment knob on high power?

Because the movement is too large and you can break the slide of you turn it the wrong way.


Why cant the coarse adjustment knob be used on high power lenses?

The coarse adjustment knob is used for making major changes to the focus, and is therefore too inaccurate to use at high powers, where only a very fine adjustment can drastically change the clarity of the picture you see.