answersLogoWhite

0

What are deaerators?

User Avatar

Anonymous

12y ago
Updated: 8/16/2019

Deaerator is Device or vessel where dissolved gases removed from the water by using steam (pressure corresponding to saturation temperature)

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

What does deaereating mean?

Deaerating refers to the process of removing dissolved gases, particularly air, from a liquid, typically water. This is often done to prevent corrosion in systems like boilers and pipelines, where oxygen can cause damage. Deaerators are commonly used in industrial applications to ensure the efficiency and longevity of equipment. The process can involve heating the liquid and reducing pressure, or using vacuum techniques to extract the gases.


What are advantages of deaerator?

A deaerator removes dissolved gases, primarily oxygen and carbon dioxide, from water, which helps prevent corrosion in boiler systems and piping. This process enhances the efficiency of steam generation by reducing the risk of scaling and fouling, leading to lower maintenance costs and increased operational reliability. Additionally, deaerators contribute to improved water quality, promoting better overall performance of thermal systems.


What is De-aerator?

A deaerator is a device that is widely used for the removal of air and other dissolved gases from the feedwater to steam generating boilers. In particular, dissolved oxygen in boiler feedwaters will cause serious corrosion damage in steam systems by attaching to the walls of metal piping and other metallic equipment and forming oxides (rust). It also combines with any dissolved carbon dioxide to form carbonic acid that causes further corrosion. Most deaerators are designed to remove oxygen down to levels of 7 ppb by weight (0.0005 cm³/L) or less.[1][2] There are two basic types of deaerators, the tray-type and the spray-type:[1][3][4][5][6] * The tray-type (also called the cascade-type) includes a vertical domed deaeration section mounted on top of a horizontal cylindrical vessel which serves as the deaerated boiler feedwater storage tank. * The spray-type consists only of a horizontal (or vertical) cylindrical vessel which serves as both the deaeration section and the boiler feedwater storage tank.


What is bleeding of steam in thermal power plant?

Bleeding of steam means Extracting steam from Turbines for heating the feed-water. Normally, there are High Pressure Heaters & Low Pressure heaters in Condensate cycle. Steam bleed out from the turbine gets into these heaters and heats up the feed-water (generally termed as Sensible Heat Addition). The steam that was bled can be re-used as condensate in Deaerators. Steam Extractions although reduce net work output but helps in overall gain in efficiency in terms of Reduced Fuel Consumption.


How do you remove oxygen from a liquid chemical?

Liqui-Cel® Contactors offer easy-to-operate, modular solutions for degassing and oxygen (O2) removal from water without chemicals and without large vacuum towers or deaerators. Liqui-Cel® Contactors also offer the benefit of simultaneous oxygen and carbon dioxide removal from water as well as N2 control with one step.aimsely.com


What are examples of mechanical separation?

Materials separatedSeparatorsLiquid from liquidSettling tanks, liquid cyclones, centrifugal decanters, coalescersGas from liquidStill tanks, deaerators, foam breakersLiquid from gasSettling chambers, cyclones, electrostatic precipitators, impingement separatorsSolid from liquidFilters, centrifugal filters, clarifiers, thickeners, sedimentation centrifuges, liquid cyclones, wet screens, magnetic separatorsLiquid from solidPresses, centrifugal extractorsSolid from gasSettling chambers, air filters, bag filters, cyclones, impingement separators, electrostatic and high- tension precipitatorsSolid from solidBy sizeScreens, air and wet classifiers, centrifugal classifiersBy otherAir and wet classifiers, centrifugal classifiers, jigs, tables,characteristicsspiral concentrators, flotation cells, dense-medium separators, magnetic separators, electrostatic separators


High pressure steam boiler feed water p and id?

Usually high pressure boiler feed water is a 3 cell control using the drum level transmitters average, Steam flow Transmitter and feed water flow transmitter The drum level controller is tuned so that the drum level is around the half glass depending on load using the steam flow as a feed forward & drum level trim (lifting the drum level above SP under high load and lowering drum level under SP for low load)and the water flow to balance out with the steam flow (mind you if you blow down or have a tube leak the drum level will open the feed water control valve to maintain level) the main tuning in the P.I.D for this is Gain and integral not using derivative as it is too abrupt in its response obviously the actual full control schematics is a lot more complex than this


What cause noise and vibration inside the deaerating feed tank?

Noise and vibration inside a deaerating feed tank can be caused by several factors, including turbulent fluid flow as water enters the tank, mechanical vibrations from pumps or other equipment, and the release of steam or gases during the deaeration process. Additionally, structural resonances can amplify these vibrations. Improper installation or alignment of components can also contribute to increased noise and vibration levels. Addressing these issues typically involves optimizing flow rates, ensuring proper equipment alignment, and using vibration-dampening materials.


What are words that have the root term?

verb decisive