The to types of microscope are as following : 1. Simple microscope 2. compound microscope differences between these both is as following: simple microscope has one Len but compound microscope has two Len.
light microscopes shoe only black and white pictures. When a compound microscope shows color when you look through the eye-piece.
A light microscope uses visible light to magnify and view specimens, offering lower magnification and resolution compared to a scanning electron microscope (SEM) which uses a focused beam of electrons to image the sample, providing higher magnification and resolution. SEM can produce 3D images of the sample surface while light microscopes typically provide 2D images.
Stereoscopic microscopes, also called low-power microscopes, dissection microscopes, or inspection microscopes, are designed for viewing "large" objects at low magnifications. Unlike a compound microscope which provides an inverted 2-dimensional image, stereo microscopes provide an erect (upright and unreversed) stereoscopic (3-dimensional) image......
silicon dioxide is a compound and diamond is an element
Atomic Force Microscopes (AFM) and Scanning Tunneling Microscopes (STM) are different types of Scanning Probe Microscopes (SPM). An AFM uses a sharp, microfabricated tip on a flexible cantilever (typically made of silicon) to scan over a surface and measure topography. An AFM uses the atomic forces between the tip and surface, hence its name. An AFM can work by simply "dragging" the tip across the surface or by oscillating the cantilever and sensing changes in the cantilever's amplitude.An STM, on the other hand, uses a tunneling current to sense the surface. The surface has to be at least somewhat conductive. The tip is typically a cut or etched wire made of Pt or Tungsten. Because the tunneling current drops off exponentially with distance, very accurate measurements can be made.The STM was the original scanning probe microscope invented. The AFM came afterwards to overcome the conductivity requirements of the STM.
The old microscopes use a mirror and the sun. It has weaker magnifying power and no stage clips. The new ones have a light source that runs on electricity. The magnifying power is stronger and it has stage clips to hold the slide in place.
Compound microscopes (also called compound light microscopes) employ light and an array of glass lenses to magnify an object. (This is distinguished from a simple microscope of one lens.) An electron microscope uses a beam of electrons to magnify an object. The lensing system employs electric and magnetic fields and is specialized for applications requiring much higher magnification. See related links.
There are many differences between a 2D and 3D barcode scanners. The most notable difference is the thickness of the lines of the barcode one is scanning.
It really depends on what new compound I have made. If I have made hydrogen hydroxide, then it is vastly different.
both are bright field microscopes, and works on two lenses
light microscopes direct light onto the slide and magnify it, light microscopes also have a high and low power objective lens which can magnify up to 10, 40, 43 and 100 times total magnification whilst electron microscopes shoot electrons at the slide which give more detail and accuracy but the disadvantage is it can't view objects in color. electron microscopes can magnify up to 500.000 times total magnification.Light microscopes aren't as strong as an electron microscope in respect to zooming power. The specimen can remain alive in light microscope but for electron microscopes, preparation of the slides will kill the specimen.