Which of the following variables are used to calculate the sensible heat load of a product?

Group of answer choices

Respiration heat, specific heat, and temperature change.

Latent heat, product weight, and temperature change.

Latent heat, product weight, and respiration heat.

Product weight, specific heat, and temperature change.

User Avatar

GREG Gilleland

Lvl 2
1y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

11y ago

the factors considered are solar, filtration, and infiltration heat gain.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What are the factors considered for heat load calculation?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you size an air conditioner for a building?

Determine the Heat Load or Gain for the building in btu or tons and choose an air conditioning system capable of removing the specified amount of heat given in the load calculation.


How are air conditioning loads calculated?

the proper way by heat load calculation, but also by ton capacity and square feet.


How do you calculate btu per square foot?

Divide the heat loss or gain obtained by the load calculation by square footage of the building.


How big a house will a 75000 btu furnace heat?

Heat load calculations need to be conducted for home to determine the proper size furnace. There is no simple answer to this question. There are a number of factors that can effect what size your furnace should be. Example: square footage, duct work size, insulation factors, windows etc. I recommend having a heating professional look at your home and conduct a heat load calculation. Over sized and under sized furnaces can cause you number out problems in the long run.


what is heat load calculation?

Heat load calculation, also known as heating load calculation or cooling load calculation, is a process used in the field of HVAC (Heating, Ventilation, and Air Conditioning) engineering to determine the amount of heat energy that needs to be added or removed from a space to maintain a desired temperature and comfort level. The purpose of heat load calculation is to properly size HVAC equipment such as furnaces, air conditioners, and ventilation systems to ensure they can effectively heat or cool a building or room without overloading or underperforming. Accurate heat load calculations are crucial for designing energy-efficient and cost-effective HVAC systems. Heat load calculations take into account various factors, including: Building Size and Shape: The size and layout of the space being conditioned influence the amount of heat gain or loss. Larger spaces generally require more heating or cooling. Insulation: The type and quality of insulation in walls, floors, and ceilings impact how much heat is transferred in or out of the space. Windows and Doors: The number, size, and quality of windows and doors affect the heat transfer. Poorly insulated or single-pane windows, for example, allow more heat to escape or enter. Occupancy: The number of occupants in the space and their activities generate heat. For example, a crowded room with many people will produce more heat. Appliances and Equipment: Heat-generating equipment, such as computers, ovens, and lights, contribute to the heat load. Climate: The local climate, including outdoor temperatures and humidity levels, plays a significant role in determining heating and cooling needs. Internal Heat Gain: This includes the heat generated by lighting, electronic devices, and appliances within the space. Ventilation Rate: The amount of fresh air required for ventilation and the associated heat load must be considered. Occupancy Schedule: The hours during which the space is occupied and the desired temperature settings at different times of the day impact the heat load. By gathering data on these factors, engineers can perform calculations to determine the heat load in terms of heating (in winter) or cooling (in summer) required to maintain comfort conditions. This information is then used to select appropriately sized HVAC equipment, ductwork, and insulation to ensure efficient and effective climate control while minimizing energy consumption and costs. Additionally, it helps in designing systems that maintain indoor air quality and comfort. More detail visit at eds.tech


How do you estimate what output gas heater you require for your house?

Manual J heat load calculation. This is usually done at no charge as part of a contractors estimate.


How can you determine the best size central air conditioner for a home?

Have a reputable A/C contractor perform a Manual J(heat load calculation on your home).


What is the correct way to size an ac system by ton?

Have a Manual J heat load calculation performed on the home. This would normally be part of the process of obtaining an estimate from a contractor. Then size your ac unit to equal the amount of heat gain indicated on the load calculaton.


How do you make concrete load calculation?

get someone else to do it


What is the formula of load calculation?

There are various formula of load calculation. Power equals current multiplied by the voltage. Power can also be computed by multiplying the resistance by the square of the current.


How many sq ft would 3500 BTU heat?

You cannot use square feet to determine how much heat is required or vice versa. A Manual J heat load calculation must be performed to determine the total heat loss of any given space.


What are the factors considered in designing machine foundation?

1.Static load 2.dynamic load 3.operating frequency 4.Elastic properties of the ground