If you have a transformer with an output adequate to run the motor, use it directly for the supply to the motor control circuitry. Remember when dealing with motors, the start current will be about 300% of the full load running amperage. Size the transformer accordingly.
It's all to do with the conservation of energy. The output power of the transformer cannot be greater than the input power from the motor used to drive your generator! In fact, it will be significantly lower than the power of your first motor due to the efficiency of the motor, of the generator being driven by that motor, and of the transformer. So if you then try to run the original motor from the output of your transformer, the energy-losses will simply accumulate, and the motor will not be able to run!
Squirrel Cage motor is a kind of Induction Motor. The reason an induction motor sometimes refered to a rotating transformer is because the stator (Primary windings in a transformer), which is powered to set up a magnetic field induces a current in the armature coils (secondar coils in a transformer). However, instead of giving an electrical power output, the coil is short circuited to produce mechanical output (torque in this case)
No. You won't be able to start the motor without the capacitor.
It should work okay as long as voltage rating is equal to or greater than the capacitor you are replacing.
You can not by-pass the capacitor in an electric motor. Most are capacitor-start motors which require the capacitor to be operational in order to start. If the capacitor is not working then it will need to be replaced.
The mechanical load of a motor determines the necessary output power rating of an electric motor. As mechanical loads are defined in terms of watts (or, in North America, horse power), then motor's output must be rated in watts, too.The so-called 'power' rating of a transformer is determined by the rated voltage and the rated current of its secondary winding. The product of these two quantities is the transformer's rated 'apparent power', expressed in volt amperes.Incidentally, the symbol for "kilowatts" is "kW", not"KW's"!
Function of Capacitor in Air Conditioner:Compressor Motor Capacitor: This air conditioning capacitor usually consists of two capacitors that are combined. This vital capacitor gets the motor running in the air conditioning unit.Start Capacitor: This capacitor provides auxiliary support and that is not a standard on every air conditioning unit. It can give the motor a boost to get it started.Indoor Blower Motor Capacitor: This capacitor is self-explanatory. It is responsible for starting the indoor-blower-motor and keeping it running efficiently.Outdoor Fan Motor Capacitor: The name says it all for this capacitor. It starts the outdoor fan and keeps the air flowing through the coils that run on the outside of an air conditioner.
The load side of a transformer feeds the device, such as a light or motor. It is the output of the transformer. The input, or line side, provides the voltage that is to be transformed, either up or down, to supply the load side.AnswerA transformer's primary winding is connected to the supply voltage, and the secondary winding is connected to the load.
The fan motor is bad. The fan motor capacitor may also be the problem. First, an amperage test should be done on the motor to see if its exceeding the rated amps. Secondly, the capacitor should be tested for the amount of microfarads it has. If its an old mtor, it should be replaced, along with the capacitor. All of this should be done by a licensed A/C contractor!
The value of the capacitor for a 1hp AC motor depends on the specific motor design and manufacturer guidelines. It is important to consult the motor's documentation or contact the manufacturer to determine the correct capacitor value for proper motor operation.
A start capacitor is wired in series with the motor's start winding via a centrifugal start switch. The switch disconnects the capacitor and start winding once the motor has reached a pre-determined minimum speed. The motor then continues to run on its main field winding. A different design uses a "start-and-run" capacitor which remains in circuit whilst the motor is running.
There are 2 types of capacitor including starting capacitor and running capacitor running capacitor are used to improve the power factor of motor. starting capacitor used in split phase induction motor . starting capacitor may isolate from motor,s starting winding through of centrifugal switch after getting motor 90% of it,s rated speed.