1 HP electric motor = 1.5 HP hydraulic motor so for a 3 HP electric motor you would need a 4.5 HP hydraulic motor. Also for your information a 1 HP hydraulic motor = 1 2/3 HP gasoline engine.
10 is the gauge of the wire, 2 and 3 are how many leads are in the wire. For instance 10-2 wire is 10 gauge with two leads, 10-3 is 10 gauge with three leads.
The wire sheathing itself is usually marked. e.g. 14 CU 2 or 14/2 CU will indicate 14 gauge 2-wire (+ ground) copper (CU being the symbol for copper on the periodic table). For 15amp circuits you will likely has 14 gauge wire with most of that being 14/2 (Usually white, black, and bare copper).
GAUGE IS THICKNESS THE SMALLER THE # THE THICKER 2- THICK 22- THIN
1-0 or 1/0 actually means one zero and is thus pronounced "won aught". In the US, wire is sized per American Wire Gauge or AWG which gets larger as the gauge size gets smaller. 1 AWG wire is pretty big wire (about 1/4" in diameter). 1/0 or "0" AWG wire is a bit larger. By contrast, 4/0 (0000) AWG wire is about 1/2" in diameter). The larger the wire, the higher the current carrying capacity. AWG, Ampere Rating, Some Uses 1, 130, Small House Service 0, 150, 40 HP Motor 0000, 230, Large House Service
30 amp breaker 10 /2 gauge wire
like gauge wire?
1 HP electric motor = 1.5 HP hydraulic motor so for a 3 HP electric motor you would need a 4.5 HP hydraulic motor. Also for your information a 1 HP hydraulic motor = 1 2/3 HP gasoline engine.
Put a 12 hp motor on it.
About 1/2 hp
on a 4000 watt amp the best gauge wire woul be between 2 and 0
10-2 wire refers to 10 gauge, 2 conductor wire. Youshould use wire that is 10 gauge or larger (8 gauge, 6 gauge, 4 gauge, 2 gauge). The larger the wire, the more it will cost. most people install using the smallest size permitted, which in this case is 10 gauge. The are specifying the wire size to ensure that you do not connect the air conditioner to electric power using wire that is two small. If you are having problems with this type of question, you should consult an licensed electrician for help in connecting your air conditioner.
10 is the gauge of the wire, 2 and 3 are how many leads are in the wire. For instance 10-2 wire is 10 gauge with two leads, 10-3 is 10 gauge with three leads.
4 gauge
The wire sheathing itself is usually marked. e.g. 14 CU 2 or 14/2 CU will indicate 14 gauge 2-wire (+ ground) copper (CU being the symbol for copper on the periodic table). For 15amp circuits you will likely has 14 gauge wire with most of that being 14/2 (Usually white, black, and bare copper).
A 15 hp game fisher motor is most often a 2 stroke engine. However there can also be a 15 hp game fisher motor that is a 4 stroke as well.
Any wire size larger that a # 18 AWG can be fused at 2 amps.