I have never seen a four pole circuit breaker. Breakers are single, two and three pole. Single pole for 120 volts, two pole for 240 volts and three pole for three phase loads. In North America all neutrals are SN (solid neutrals) and are not switched.
In certain applications using a three phase Y-connected load, where complete isolation of the load from the supply is required, the neutral line connects to one pole of a 4 pole circuit breaker.
its a circuit breaker that has like four interrupters. It usually has like a double pole and two single poles all in one. it will just look like four single poles glued together
A pole In a circut breaker refers to the number of circuts it controls, single pole only controls one, double controls 2 at same time
U.S. 240 VAC breakers are always double pole since they are protecting two legs of the circuit.
Earth leakage miniature circuit breaker (mcb+ecb=rcbo) rcbo is called elcmb
A single phase circuit uses a 2 pole breaker if the circuit is 120/240 split phase and the load is connected 240. Both legs are hot, so both need to be protected. This is the normal US/Canada configuration.
Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.
before the load
Replacement for American Switch single pole 15 amp circuit breaker
TPN means three pole with one pole neutral connected.
3 pole would be for 3 phase, 4 pole would be 3 phase & neutral
A pole In a circut breaker refers to the number of circuts it controls, single pole only controls one, double controls 2 at same time
U.S. 240 VAC breakers are always double pole since they are protecting two legs of the circuit.
Earth leakage miniature circuit breaker (mcb+ecb=rcbo) rcbo is called elcmb
A single phase circuit uses a 2 pole breaker if the circuit is 120/240 split phase and the load is connected 240. Both legs are hot, so both need to be protected. This is the normal US/Canada configuration.
A GE tandem breaker can be removed and replaced with a GE single pole breaker.
Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.
The term "double pole" usually means a breaker with 2 handles that attaches in the space as a normal single pole breaker. If this is what you mean, no, you cannot. There is no potential, or voltage, between the wire terminals. If by "double pole" you mean what is usually called a 2-pole breaker, which is a breaker with 2 handles that attaches in the space of 2 single pole breakers, then yes, you can use this breaker and 12/2 wire to produce a 220v circuit.
A circuit breaker is a switching device which can make,brake and carrying (or trip the circuit) that specified over currents for a small interval of time . There is a different types of Circuit Breaker's are there 1.According to their arc quenching media these are divided into 4 types a) Oil circuit breaker b) Air blast circuit breaker c) SF6 circuit breaker d) vacuum circuit breaker 2. According to their services the circuit breaker can be divided as a) Outdoor Circuit Breaker b) Indoor Breaker 3. According to the operating mechanism of circuit breaker they can be divided as a) Spring operated Circuit Breaker b) Pneumatic Circuit Breaker c) Hydrolic Circuit Breaker 4. According to the voltage level of installation these are divided into 3 types a) High Voltage Circuit Breaker b) Medium Voltage Circuit Breaker c) Low Voltage Circuit Breaker.