answersLogoWhite

0

When a transformer is first energized, a transient current up to 10 to 50 times larger than the rated transformer current can flow for several cycles. Toroidal Transformers, using less copper for the same power handling, can have up to 60 times inrush to running current. Worst case inrush happens when the primary winding is connected at an instant around the zero-crossing of the primary voltage, (which for a pure inductance would be the current maximum in the AC cycle) and if the polarity of the voltage half cycle has the same polarity as the remnance in the iron core has. (The magnetic remanance was left high from a preceding half cycle). Unless the windings and core are sized to normally never exceed 50% of saturation, (and in an efficient transformer they never are, such a construction would be overly heavy and inefficient) then during such a start up the core will be saturated. This can also be expressed as the remnant magnetism in normal operation is nearly as high as the saturation magnetism at the "knee" of the hysteresis loop. Once the core saturates however, the winding inductance appears greatly reduced, and only the resistance of the primary side windings and the impedance of the power line are limiting the current. As saturation occurs for part half cycles only, harmonic rich waveforms can be generated, and can cause problems to other equipment.

For large Transformers with low winding resistance and high inductance, these inrush currents can last for several seconds until the transient has died away (decay time proportional to ~XL/R)and the regular AC equilibrium is established. To avoid magnetic inrush, only for transformers with an air gap in the core, the inductive load needs to be synchronously connected near a supply voltage peak, in contrast with the zero voltage switching which is desirable to minimize sharp edged current transients with resistive loads such as high power heaters. But for toroidal transformers only a premagnetising procedure before switching on allows to start those transformers without any inrush current peak.

User Avatar

Raheem Raynor

Lvl 10
2y ago

What else can I help you with?

Related Questions

Magnetic inrush current in power transformer with waveforms?

The mgnetic inrush current is the current drawn by the transformer when power is applied to the primary winding


Magnetic inrush current in power transformer?

When a transformer is initially connected to a source of AC voltage, there may be a substantial surge of current through the primary winding called inrush current. Inrush current can be up to ten times higher than the continuously needed current because there is low initial resistance.


What is the difference between the inrush current and the fault current?

Magnetizing inrush current has bigger 2nd harmonics compare to short circuit current. the second harmonics content is about >60% of fundamental harmonic. magnetizing inrush current happened when we energised the transformer, and short circuit current happened if there is a short circuit between different alive phase.


What are the functions of current transformers and the difference between current transformers and voltage transformers?

To sense the current flow across the current transformers and to monitor the current ratings. In current transformers no voltage variations occurs. but in voltage transformers it is mainly used to increase or decrease the voltage value.


How inrush current limited in ups?

Omg girlz sign in the gorop


More the transformer impedance less the fault current... so is a high value of transformer impedance good for it?

It depends a lot on the application, i would go with low impedance transformers if am using the transformers for distribution as it will really increase the the maximum fault current. If am using the transformers as step up specially for generators or to charge capacitors, using a high impedance transformer is a good idea as it will decrease the inrush current of the system. you have to see your application and decide what fit that best. Mohammad Jaradat Power Generation Project Manager


Who would need to utilise current transformers?

A current transformer is used for measurement of alternating electric currents. Current transformers, together with voltage transformers are known as instrument transformers.


What is the inrush current for halogen?

Halogen bulbs typically have an inrush current that is approximately 10 to 12 times their operating current. This high initial current draw is due to the cold resistance of the filament and the initial surge required to heat it up to operating temperature.


What is Direct online Starter and its disadvantage?

Across the line starter has a large inrush current.


Can we drive relays by current transformers?

Yes, certain types of relays can be activated by current transformers.


Are Transformers used in circuits with Direct Current?

No. Transformers are used in circuits with Alternating Current. Transformers work on the principle of a "changing" magnetic field inducing a current in a conductor, and you don't get that "changing" field with Direct Current.


Acids conduct electric current by forming what?

By direct from the manufacturer! Current & Potential Transformers