Q: What is max pressure for air con system being charged with R410a refrigerant?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the internal pressure of a cylinder with one ounce of liquid R410A refrigerant which has been sitting in a 100 degree Fahrenheit truck?

?


What are the correct pressures for R410a?

The pressure for an R410a air conditioner system should be 118psi LP and 412psi HP. This is the same pressure as an R22 air conditioner.


What licence do you need to buy r-22 or r410a refrigerant?

R22 needs import license,R410A does not need anything special


What type of refrigerant is used in a ac?

R134A, R22A, R404A, R410A and many more


Which refrigerant has the lowest condensing temperature R12 or R22 or R500 or R410a?

R-12..........


Explain what Refrigeration Compatibility means in relation to refrigeration oils?

There are different types of refrigerant oils. Refrigerants such as R22 and R12 usually use mineral oil. But some of blended refrigerants like R410A can sometimes use a poly oil. These oils can not be blended together. So a system that already has a refrigerant with mineral oil must be charged with refrigerants with the same oil.


What refrigerant is now used in home central ac units?

Most new equipment is built for and charged with R410a, a refrigerant with much higher pressures than the R22 used for decades, R22 units are still available, dry charged however, you must fill them with R22 onsite. This is how new R22 compatible equipments being sold still.


Will a new r22 coil work with 410 refrigerant?

An R22 coil will work properly with R410A only ifseveral conditions are met.First, the manufacturer of the coil must specify that it will work with both refrigerants. R410A systems operate at about 40 to 70 % higher pressure than R22 systems.Second, the new coil must be equipped with an inlet control (either a thermal expansion valve or orifice) that is intended for R410A. The new coil may not use a capillary tube metering system to control refrigerant flow into the evaporator coils.Third, the tonnage, or Btu capacity, of the coil and control device, and the EER/SEER of the coil must match those same ratings for the condensing unit.Fourth, if the new coil has been used in an R22 system, it must be thoroughly flushed clean of oil, and must be refitted with the proper control valving for R410A.


How much R410 a freone does it take to contaminate a R22 freone system?

Any amount would be a contamination. Charging with clean R410a does not introduce POA oil, which is where a serious contamination would occur. Mixing R410a without oil will simply render that amount of charge in your system as ineffective. To answer the question how much contaminates, it could be seen on a sliding scale, a very small amount, say a couple ounces, probably will not see a noticeable change. A pound, and you would likely notice some changes in performance related to temps. of evaporator as well as the amount of liquid refrigerant its producing to send to the evaporator. As you increase the ratio of R410a to R22, you would only see incrementally worse performance as the compressor is not producing the pressure required to get any use of R410a. If you had somehow introduced R410a with its oil, their would be a serious reason to pull the entire charge, flush the system, and start clean. The oils of R22 and R410a are %100 not mixable, they will be rendered useless, and system damage will occur shortly.


Can you use a r410a condenser brand new with a r22 air handler brand new?

No. r410a runs at a much higher pressure.


What is the maximum reading on a typical r410a high pressure gauge?

800psig.


How do you charge a R410a air conditioner?

hook up your guages, look for the system pressures. the high side should be around 800psi. the low side should be around 400psi. if your pressures are below this charge accordingly. if you have a system leak, pump some bacon grease in the system. it works wonders!! then when you are fininished dump the rest in your pan and cook you a celebration dinner. enjoy your properly charged r410a system!!