The maximum single phase HP motor listed in the CEC is 10 HP. At 115 volts 100 amps and 230 volts 50 amps.
..the questions does not say wether the 30kVA transformer is 3 phase transformer or single phase transformer..but it is implying that a single phase welding load at 16A per phase is to be connect to it, it is assumed then that the transformer is 3 phase transformer..we assume load is rated 240V.. ..though not much details is given about the transformer voltage specs. but if is rated 3 phase 415/240V, the approx full load current per phase is given by 30KVAx1.3912=41.736A.. ..but if the transformer was rated single phase 240V say, the approx full load current FLC=30000/240V gives 125ampers.. ..if you further devide the FLC by the intended load current.. ..Recommended no of welders per for a 3 phase 415V transformer and assuming single welding sets =41.736/16=2.6..so you can connect max two welding sets to this transformer per phase,..max 6 weld sets can connect at an approx load factor of 76%.. ..for the single phase transformer, FLC/16=125/16, gives 7.8 but is also recommended not to connect more than 6 welding sets to such transformer for the same reasons..
Single Phase motorRPM (Revolution Per Minute) depends on Frequency used & the number of poles of motor.So this RPM of single phase motor usually 300 to 3000 depending upon F & P.
NEC does not have a CEO per se. However, the President is Nobuhiro Endo.
If, by 'unit price', you mean the cost per kilowatt hour, then there is normally no difference between the cost of energy supplied whether by single-phase or three-phase supplies.
What is the max dosage per day for Demerol
Single phase alters from positive to negative at 50 (50hz) or 60 (60hz) times per minute. While in dc it does not vary but stays at a constant positive phase.
The choice of single or three phase depends on the available supply. But a three-phase full wave rectifier provides 6 pulses of DC per cycle, while a single-phase full-wave rectifier provides only two. That makes the output DC easier to smooth.
Basically the formula is I = P / V where I = amps, P = power (kV) and V = volts for a single phase 11 kV genset the formula is 11000/400 = 27.5 amps max load. For a 3 PHASE GEN then 11000x0.8/400/3 = 7.3 amps per phase.
No point on a countertop can be more than 24 inches from a receptacle per NEC 210.52. They have to be GFCI outlets per NEC 210.8.
The kV.A (not 'kva') rating is the total apparent power of the machine. So a 75 kV.A machine is 25 kV.A per phase.
Regulation =(Obtained voltage per phase - rated voltage per phase)/rated voltage per phase *100