answersLogoWhite

0

Rising stem gate Valve- Stem threads are out side of valve body and in no contact with fluid medium. Stem rises while opening the valve (by hand wheel). Since the stem threads are located outside obviously it needs some more vertical clearance space while opening the valve.

Non Rising Stem gate Valve - Stem threads are inside the the valve body and it is in contact with fluid medium. Hence, lot of chances for fouling the threads and these types of valves only can be used in clean liquids and gases. Less vertical clearance space required while opening the valve.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Engineering

What is the difference between a control valve and a gate valve in a stand pipe system?

a gate valve is a one way totally open or closed valve, a control valve is a variable valve.


What is the difference between a knife gate valve a gate valve?

A Knife Gate Valve is used to slice through sludge /sewerage and a gate is used fro normal positive shut off If you want to find the photo of Knife Gate Valve,you can enter to the link:http://www.kolinkcn.com/


What is the difference between gate valve and OS and Y valve?

OS and Y stands for Opposed Stem and Yoke.


What is the difference between gate valve and globe valve?

The external housing (shell) of gate and globe valves are similar, but the globe valve is designed to serve as a regulating valve, meaning that it can adjust the flow by the percentage of the opening. However, the gate valve is not designed to regulate flow, but to stop the flow. A gate valve should always be either fully open or fully closed. The main difference is in the form of the inner elements and the form of the flow inside the valves. In addition, the gate valve may have a rising or non rising stem while the globe valve is typically a rising stem design. The direction of flow through a gate valve is not important. However a globe valve has a flow direction indicated on the outer shell (body) which indicates the direction of flow from beneath the seat. In a gate valve, the closure element is a plate or disk which travels parallel to the plane of the seat. The gate in a dam is a well known example. In a globe valve, the closure element is usually called a "poppet", and it travels perpendicular to the plane of the seat. There are specific advantages and disadvantages to each type depending on the application. The application for a globe valve is regulating flow. It is not well suited for full stop isolation. The gate valve is an isolation valve and not designed to regulate flow.


What is NRS in term of gate Valve?

Non rising stem of a globe valve refered as NRS.

Related Questions

What is the difference between an slide gate and a sluice gate valve?

The difference is that a sluice gate is made out of cast iron while a slide gate isn't.


What is the difference between a control valve and a gate valve in a stand pipe system?

a gate valve is a one way totally open or closed valve, a control valve is a variable valve.


What is the difference between a knife gate valve a gate valve?

A Knife Gate Valve is used to slice through sludge /sewerage and a gate is used fro normal positive shut off If you want to find the photo of Knife Gate Valve,you can enter to the link:http://www.kolinkcn.com/


What is the difference between gate valve and OS and Y valve?

OS and Y stands for Opposed Stem and Yoke.


Difference between globe valve and gate valve?

The Gate valve is the stop valve & the Globe valve is the fluid Regulating valve.


What is the difference between gate valve and globe valve?

The external housing (shell) of gate and globe valves are similar, but the globe valve is designed to serve as a regulating valve, meaning that it can adjust the flow by the percentage of the opening. However, the gate valve is not designed to regulate flow, but to stop the flow. A gate valve should always be either fully open or fully closed. The main difference is in the form of the inner elements and the form of the flow inside the valves. In addition, the gate valve may have a rising or non rising stem while the globe valve is typically a rising stem design. The direction of flow through a gate valve is not important. However a globe valve has a flow direction indicated on the outer shell (body) which indicates the direction of flow from beneath the seat. In a gate valve, the closure element is a plate or disk which travels parallel to the plane of the seat. The gate in a dam is a well known example. In a globe valve, the closure element is usually called a "poppet", and it travels perpendicular to the plane of the seat. There are specific advantages and disadvantages to each type depending on the application. The application for a globe valve is regulating flow. It is not well suited for full stop isolation. The gate valve is an isolation valve and not designed to regulate flow.


What is NRS in term of gate Valve?

Non rising stem of a globe valve refered as NRS.


What is the difference between an air valve and gate valve?

An air valve is a spring loaded plastic valve for ventilation. A gate valve is an old fashioned type of water valve where turning a handle lowers a blocking gate over the water inlet. Any sensible plumber now uses ball valves instead.


What is the difference of gate valve to gate valve?

a gate valve is a valve you turn the handle round and round until it shuts off a ball valve is a valve with a lever that you turn 1/4 turn and its off hope this helps plumber paul


Is there an Open and close indicator for a gate valve?

Yes buy a RISING Stem type


How to Install a Gate Air Valve?

Unlike traditional check valves, gate valves have very low flow resistance, thanks to the straight-through design of the wetted area. Stainless steel is also corrosion-resistant, and will not leach into the medium it passes through. It can be used in areas where corrosive fluids are present, and it can be used in drinking water. Despite its low resistance to fluids, the valve is relatively easy to maintain. Before installation, clean the sealing surface and cavity of the gate valve, and tighten the packing. The valve seat is attached to the body of the valve by a screw and can be either rising or falling. When fully opened, a gate valve exposes the stem of the gate. A sealing gland in the body compresses the packing and creates a tight seal. A rising stem gate valve is suitable for above-ground installation. The valve is not recommended for use with corrosive liquids. It is advisable to install a gate valve with a high-flow capacity. The stem of a gate valve is attached to the body of the valve. The rising stem is connected directly to the gate. This is a visual indication of the valve's position. The nonrising stem is threaded into the body and has a pointer at the top. It is best suited for applications that have little vertical space and do not want to scrape. If a rising stem is necessary, it should be installed with the valve's body. A gate valve has two parts. The body is the largest. The valve's spindle is attached to the body. The body contains two springs which act as hinges. The spring is an internal component that provides a tight seal. A spherical valve is more efficient than a lever valve. A pressure-sensitive model is a type of ball valve. This design also provides higher pressure than the other type. The bonnet is made from steel. A gate valve has two types of bonnets: a non-rising stem and a rising stem. The rising stem is used in high pressure service. In a non-rising stem, the stem is stationary. The non-rising stem has a single disc. During a closed valve, the disc and the stem move up and apart. The media is then allowed to pass through. The fully open gate valve provides minimal resistance and little pressure drop. A gate valve has two types of seats: the rising and the falling stem. The rising stem is fixed to the gate and rises and falls together with the valve. The rising stem is fixed to the gate, while the sinking one is mounted between two seats. The rising and the falling stem are fixed together. The roses and falling stems are connected to each other by a threaded rod, which is threaded into the valve. The wedged gate is the most common type. It has two inclined seats. When the gate is closed, it will not stick to the seat. A wedge-shaped valve can be used for high-pressure applications. However, it is not recommended for use in corrosive fluids. Its flexibility allows it to withstand high-pressure conditions, such as high-temperature environments. The flexible wedge is a good choice for corrosive fluids. AVK Singapore Pte Limited Address: 40 Gambas Crescent Nordcom 2 757018 Singapore Telephone : +6562141048 Working Hours - 9:30 AM to 6:00 PM


How many turns does it take to shut an 18 inch gate valve?

The number of turns required to shut an 18-inch gate valve typically ranges from 3 to 8 full turns, depending on the valve's design and the specific manufacturer. Gate valves often have a rising or non-rising stem, which can also influence the number of turns needed. It's essential to consult the valve's specifications for accurate information.