Two phase motors are a thing of the past and are not used today if any still exist. Two phase legs are classified as a single phase system.

If the question refers to a dual voltage motor then the answer depends upon what supply voltages are available to operate the motor. Operating a motor at the higher of the two voltages means that smaller control equipment and wire feeders can be used to operate the motor.

If the nameplate is checked, in the amperage box there will be two current ratings, Amps/Amps. One will be half of the other one. Look at the supply voltage box and you will see the corresponding Voltage/Voltage. The first number in the voltage box corresponds to the first number in the amperage box.

The higher the voltage the less line loss will occur over a distance. If possible always try and use the highest voltage to operate motors.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the advantage of using two phase in single phase motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can i run single phase dc motor from 3phase bldc controller. i m using single phase motor in motorcycle and controller from other electric vehicle. if yes please tell me how to connect it?

It is possible to run a DC motor on a 3-phase supply using a full-wave rectifier if the voltage is right.


How much kva is required to run a single phase 5hp motor using generator?

To answer this question the voltage of the motor is needed.


Single phase to three phase conveter for driving three phase motor using single phase?

This inverter is the cheapest and always available from famous vendors like ROCKWELL ,ABB, SIEMENS ,SCHNEIDER ELECTRIC....etc .


Can a 3 phase motor be converted into a single phase motor?

A three-phase motor will not start if one or two phases aren't connected. If while running one or two phases "drop out", it will continue to run for awhile, but will eventually burn out, unless connected to a motor saver.


What motor gets more heated single phase or three phase?

Your question is a little like asking, 'How long is a piece of string?'! Do the two motors have the same power rating, or are they different?The rate at which energy is used by any machine is defined by its power rating. If the power ratings of two different machines are the same, then both machines use energy at the same rate. So if a single-phase motor has the same power rating as a three-phase motor, then they will both use exactly the same amount of energy over a given period of time.So, if a single-phase motor has a greater power rating than a three-phase motor, then the single-phase motor will the greater amount of energy in a given period. On the other hand, if a three-phase motor has a greater power rating than a single-phase motor, then the three-phase motor will the greater amount of energy in a given period.


What is phase 3?

It is a short-hand description of the torque from a 3-phase motor. By the nature of 3-phase electricity, a motor using it gives a constant torque, unlike a single-phase motor which gives a torque that pulsates at twice the supply frequency. Usually that does not matter because there is enough inertia in the rotating parts to mask the effect.


What is a 3 phase?

It is a short-hand description of the torque from a 3-phase motor. By the nature of 3-phase electricity, a motor using it gives a constant torque, unlike a single-phase motor which gives a torque that pulsates at twice the supply frequency. Usually that does not matter because there is enough inertia in the rotating parts to mask the effect.


What is a 3 phase torque?

It is a short-hand description of the torque from a 3-phase motor. By the nature of 3-phase electricity, a motor using it gives a constant torque, unlike a single-phase motor which gives a torque that pulsates at twice the supply frequency. Usually that does not matter because there is enough inertia in the rotating parts to mask the effect.


Can you reverse the wiring to make the fan reverse?

Yes if it's a dc motor with a permanent magnet field, or if it's a 3-phase ac motor. No if it's a single-phase ac motor or a dc motor with a field winding in series or parallel with the armature. <<>> Single phase AC motors can be reversed by using a reversing switch. Reverse either the start winding or the run winding connections but not both.


Why a single phase induction motor is not self starting?

Single phase induction motor is not self starting because, when the main winding is excited from a single phase supply, it produces an alternating magnetic field instead of rotating magnetic field in two phase and 3 phase induction motor. According to double field revolving theory any alternating vector can be resolved into two vectors rotating in opposite directions, each having magnitude equal to one half the magnitude of the actual vector. The vectors will be rotating in such a way that their resultant will be zero at every instant. Thus a single phase induction motor fails to produce a net starting torque, and is not self starting.It can be made self starting by any of the methods below1) By using an aux winding in series with a very high resistance2) using two capacitors,in series with the aux wdg,one with intermittent duty and the other one with continuous duty3) Using shaded poles


How do you control rpm of single phase motor without using variable frequency drive?

By changing the voltage through a potentiometer ( eg fan regulator )


Can a 3 phase motor be wired to run in your house?

The physical internal windings between single phase and three phase motors makes this an impossibility That being said money can make anything happen. Depending on the amount of money you want to spend to make this happen there is a device on the market called a VFD ( Variable Frequency Drive). On the three phase input terminals you apply your single phase voltage. On the output terminals you connect your three phase motor. When run in this configuration there is an internal switch that has to be changed to let the VFD know that it should be looking for only two lines on the input to be hot. Otherwise the VFD thinks that there is a line loss on the three phase input terminals and the unit will not start. You can make a phase converter with a couple extra motors. Wire up a 120V single phase motor and couple it to a 3 phase motor. This turns the 3 phase motor into a generator for you to run to whatever equipment the 3 phase motor is. Although if you had a single phase motor you probable don't need a 3 phase motor. == == yes! you will have to buy a phase converter. yes, it is possible to this with a rotary phase converter . one manufacturer is "phase master" (as an example only, not wishing to promote any brand). these are not cheap units and it may be more cost effective to purchase a single phase (220V.) replacement motor . the overall efficiency (operational costs) would be better too . a rotary phase converter is usually the "last choice on the list" .